The AirTAC Airtac GFR Filter Regulator GFR300C15MNK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR300C15MNK is an AirTAC G-series filter regulator: filtration and pressure regulation in one body, with a drain bowl but no lubricator. This PT1/2 size-300 unit carries the standard 40 um element, a manual drain bowl in polycarbonate, a mounting bracket as standard, no pressure gauge, and a reverse/check valve fitted so downstream pressure is held back from the inlet side. One part does the filtering and regulating where a circuit needs that check function.
It is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, filter grades of 40 um standard or 5 um optional, manual, automatic or differential-pressure drain, and optional G (BSPP) or NPT thread. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.
| Model | Airtac GFR Filter Regulator GFR300C15MNK |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Conditioned supply to directional-valve manifolds on process skids, where the check valve isolates downstream pressure during inlet-side work.
Filtering and regulating shop air on service vehicles fitted with compressors, where supply interruptions are common and downstream pressure must be retained.
Regulated air to component test benches that hold a set pressure on the workpiece, with the check valve supporting the downstream side between cycles.
Decodable choices on this unit: size 300 with a PT1/2 port; standard 40 um filtration; manual drain, setting the regulator adjust range at 0.05-0.9 MPa (7-130 psi); no gauge (an embedded square or external round gauge can be ordered); bracket included; and the K suffix meaning a reverse/check valve is fitted. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. If your demand needs a bigger port, step up a size - but published flow is given as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Flow for this series is published as curves rather than a single rated figure, so we do not state a number here. Share your application pressures and demand and we will confirm the flow and datasheet figures for this model on request.
K indicates a reverse/check valve is fitted, so air will not flow back through the unit from the downstream side. If you do not need that function, the same unit without the K suffix is the GFR300C15MN.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.