verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR300C15MNK

The AirTAC Airtac GFR Filter Regulator GFR300C15MNK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$52.72 $57.71Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR300C15MNK

GFR300C15MNK is an AirTAC G-series filter regulator: filtration and pressure regulation in one body, with a drain bowl but no lubricator. This PT1/2 size-300 unit carries the standard 40 um element, a manual drain bowl in polycarbonate, a mounting bracket as standard, no pressure gauge, and a reverse/check valve fitted so downstream pressure is held back from the inlet side. One part does the filtering and regulating where a circuit needs that check function.

It is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, filter grades of 40 um standard or 5 um optional, manual, automatic or differential-pressure drain, and optional G (BSPP) or NPT thread. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.

Airtac GFR Filter Regulator GFR300C15MNK Technical Specifications

ModelAirtac GFR Filter Regulator GFR300C15MNK
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR300C15MNK

GFR300G-series filter regulator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR300C15MNK Is Used

valve

Pneumatic valve manifold feed

Conditioned supply to directional-valve manifolds on process skids, where the check valve isolates downstream pressure during inlet-side work.

build

Mobile service-truck air systems

Filtering and regulating shop air on service vehicles fitted with compressors, where supply interruptions are common and downstream pressure must be retained.

engineering

Test-rig pressure hold

Regulated air to component test benches that hold a set pressure on the workpiece, with the check valve supporting the downstream side between cycles.

Is the Airtac GFR Filter Regulator GFR300C15MNK the Right Unit?

Decodable choices on this unit: size 300 with a PT1/2 port; standard 40 um filtration; manual drain, setting the regulator adjust range at 0.05-0.9 MPa (7-130 psi); no gauge (an embedded square or external round gauge can be ordered); bracket included; and the K suffix meaning a reverse/check valve is fitted. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. If your demand needs a bigger port, step up a size - but published flow is given as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR300C15MNK FAQ

Flow for this series is published as curves rather than a single rated figure, so we do not state a number here. Share your application pressures and demand and we will confirm the flow and datasheet figures for this model on request.

K indicates a reverse/check valve is fitted, so air will not flow back through the unit from the downstream side. If you do not need that function, the same unit without the K suffix is the GFR300C15MN.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR300C15MNK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C15MNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.