The AirTAC AirTAC GFR200C06MC2G Filter Regulator G1/8 Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MC2G is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in one compact body. This size 200 unit is threaded G1/8 (BSPP), uses a manual drain on the bowl, and carries the standard 40 um filter element. Outlet pressure is adjustable across 0.05-0.9 MPa (7-130 psi), and a round psi gauge is fitted so the set point can be read and adjusted at a glance. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR series is published in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, a choice of manual, automatic or differential-pressure drain, an optional 5 um filter element (code W), gauge scale choices in MPa, psi or bar, and G or NPT thread alternatives to the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | AirTAC GFR200C06MC2G Filter Regulator G1/8 Manual Drain |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Mounted upstream of solenoid valves on a packaging machine, this unit strips water and pipe-scale from the shop air line and holds a steady set pressure, so valve spools and seals are not exposed to condensate or pressure drift.
Fitted at the drop leg feeding a small bench-mounted pneumatic press or clamping fixture, it lets the operator set and read the working pressure on the psi gauge while the 40 um element keeps rust and dirt out of the cylinder.
Installed at individual machine drop legs in a workshop fed from a central compressor, the GFR200C06MC2G gives each machine its own water removal and pressure setting instead of relying on a single regulator at the compressor.
Size 200 with a G1/8 port suits circuits whose air demand sits in the small-port range; step up to sizes 300, 400 or 600 when required flow outgrows the port. The manual drain on this code means an operator opens the drain to discharge collected water - choose the automatic or differential-pressure drain codes if the unit will be mounted where regular draining is impractical. The 40 um element is the standard grade; specify W for 5 um where finer filtration is needed. Thread here is G (BSPP); PT is the standard and NPT is an order option. A mounting bracket is included.
Because AirTAC publishes flow as curves rather than a single rated figure, we do not quote a flow number here. Send us your application's air demand and we will confirm sizing and the full datasheet with you before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR-series flow as curves rather than a single rated figure, so we do not quote a flow number here. Tell us your application's air demand and we will confirm the sizing and the full datasheet on request before you order.
With the manual drain (code M), an operator opens the drain to discharge water collected in the bowl - simple and reliable where the unit is easy to reach. If the unit will be mounted in an awkward spot or condensate builds up quickly, the same series is available with automatic (code A) or differential-pressure (blank) drain codes instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.