The AirTAC AirTAC GFR200C06MC3WTK Filter Regulator 1/8 NPT 5um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MC3WTK is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with a 1/8 in NPT port, a fine 5 um filter element (the standard element is 40 um; W selects the finer grade), a manual drain on the bowl, a round pressure gauge with a bar scale, and a reverse (check) valve fitted. The manual drain means an operator opens the bowl drain to discharge collected condensate, which suits installations checked as part of a routine. The polycarbonate bowl keeps the condensate level visible, and the mounting bracket is included for securing the unit to a panel or frame.
This is a genuine AirTAC part from the GFR filter-regulator line, available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of PT, G (BSPP) or NPT thread, differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge styles and scales, and an optional low-pressure regulator type. Maximum working (inlet) pressure is 1.0 MPa (145 psi), the regulating range on this manual-drain version is 0.05-0.9 MPa (7-130 psi), and the working temperature range is -5 to 70 C (non-freezing). Rated flow is published as curves rather than a single figure, so ask us and we will confirm the datasheet and flow figures for your application on request.
| Model | AirTAC GFR200C06MC3WTK Filter Regulator 1/8 NPT 5um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding the clamping cylinders on a benchtop pneumatic press: the 5 um element keeps sludge and pipe scale out of the clamping valve, the regulator sets the clamping force pressure, and the check valve holds the clamp circuit if shop air dips mid-cycle.
Conditioning the air to the sealing and sorting actuators on a carton packaging line: the filter-regulator cleans and sets the supply pressure at each machine drop, the manual drain is emptied during shift-start checks, and the bar gauge gives the operator a local pressure reading.
Supplying air to sample-handling actuators and purge lines on laboratory automation: the 5 um grade suits the finer valves and tubing on analytical equipment, the 1/8 in NPT port matches compact instrument fittings, and the bracket secures the unit inside the instrument cabinet.
Size and port are the first choice: the 200 frame with its 1/8 in NPT port is the compact end of the GFR range, so step up to size 300, 400 or 600 when the line demands more flow - match the port step to your piping rather than oversizing the body. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order. The remaining choices are all decodable from the code: drain type (manual here; automatic or differential-pressure are available if you prefer hands-off condensate removal), filter grade (this unit carries the 5 um W element instead of the 40 um standard - choose 5 um where downstream instruments or valves need finer air), gauge (this configuration includes a round gauge with a bar scale; embedded square gauges and MPa/psi scales are the alternatives), thread (PT is the standard; G and NPT are order options - this unit is NPT), and the reverse/check valve, which is fitted here to hold downstream pressure if the upstream supply drops. A mounting bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated number, so we do not quote a Cv, SCFM or l/min figure. Send us your application - line pressure, downstream consumption and acceptable pressure drop - and we will confirm the datasheet and flow curves for this 1/8 in, size-200 unit on request before you order.
The M in the code selects a manual drain: an operator opens the bowl drain to discharge collected water, which suits stations that are checked on a routine. If you would rather not rely on manual draining, the same GFR200 filter regulator is available with an automatic drain (code A) or the differential-pressure drain that is the default - note the regulation range differs by drain type: 0.05-0.9 MPa (7-130 psi) on this manual-drain version versus 0.15-0.9 MPa (20-130 psi) on the automatic and differential-pressure versions.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.