The AirTAC AirTAC GFR200C06MF2K Filter Regulator 1/8 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06MF2K is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body, holding set pressure anywhere from 0.05 to 0.9 MPa (7 to 130 psi). This size-200 unit is threaded PT1/8 (1/8 in), carries a manual drain on its metal bowl, a 40 um filter element, an embedded square gauge reading in psi, and a reverse (check) valve fitted; a mounting bracket is included.
It is a genuine AirTAC part. The GFR family is made in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, plus drain, filter-grade, gauge, thread and bracket options to match the line. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.
| Model | AirTAC GFR200C06MF2K Filter Regulator 1/8 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding the clamping cylinders on a small pneumatic press: the filter stage strips water and particulate from the shop-air drop, the regulator holds a steady clamping pressure, and the psi gauge gives the operator a local reading at the setpoint.
Conditioning air to the cylinders and actuators on a cartoning or case-sealing conveyor line: clean, regulated air helps the sequence valves and cylinders repeat their strokes, and the fitted check valve holds the setting if supply dips.
Point-of-use conditioning on a laboratory or test-bench compressed-air drop: moisture and particulate are removed before sensitive instruments, and pressure is set by hand at the bench with the psi gauge confirming the setting.
The real choices in this family are all decodable from the code. Step through sizes 200/300/400/600 and ports 1/8 in to 1 in as your air demand grows - the published flow curves, not a single rated number, are the sizing reference. Drain type: this unit is manual (the bowl is drained by hand); automatic and differential-pressure drains are available on other codes for lines that cannot be attended. Filter grade is 40 um standard, with 5 um (code W) where finer filtration is needed. The embedded square gauge on this unit reads psi; MPa and bar scales and an external round gauge are options. Thread is PT as standard, with G (BSPP) and NPT as order options, and the bracket is included on this code. Because flow is published as curves, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes filter-regulator flow as curves rather than a single rated figure, so we do not quote one number here. Tell us your inlet pressure, set pressure and expected air demand, and we will confirm the flow from the datasheet for this exact model before you order.
This code carries M for a manual drain: someone opens the drain to expel the water collected in the bowl. If the unit is mounted where it cannot be attended, choose an automatic-drain (A) or differential-pressure-drain (blank) variant of the same GFR200 filter regulator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.