The AirTAC AirTAC GFR200C06MLJC2WG Filter Regulator G1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLJC2WG is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the 200 size with a G1/8 (BSPP) port, a 5 um filtration element, a manual drain, the low-pressure regulator type, and a fitted round pressure gauge reading in psi. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The bowl on this unit is metal, and it is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options include 40 um or 5 um filtration, differential-pressure, automatic or manual drains, embedded square or external round gauges with MPa, psi or bar scales, G or NPT threads alongside the PT standard, and a reverse/check valve. Flow for this family is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | AirTAC GFR200C06MLJC2WG Filter Regulator G1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, low-pressure regulated air feeding grippers and clamping cylinders on an assembly robot, where the 5 um element protects pilot valves and the round psi gauge lets operators set and verify clamp pressure.
Air supply to heat-sealing and labeling heads on a packaging conveyor: the low-pressure regulator holds the set pressure the sealing cylinders need, and the manual drain lets maintenance purge collected water at shift start.
Clean, regulated air for instruments and small actuators on a lab or test bench, where the 5 um grade keeps sensitive components free of particulate and the compact 200 size fits tight panels.
Size and port set the air capacity: the 200 size with a G1/8 port is the smallest step in the GFR range, so step up to 300, 400 or 600 if your circuit needs more air. This unit carries the 5 um element (code W) instead of the 40 um standard - choose 5 um where pilot valves, instruments or spray equipment need cleaner air. The manual drain (code M) is emptied by hand, unlike the automatic or differential-pressure drain options. The regulator is the low-pressure (L) type, intended for lower set pressures; its exact adjustment range is not published, so confirm it with us. The fitted round gauge reads in psi; an embedded square gauge with MPa, psi or bar scales is the alternative. The thread here is G (BSPP); PT is the standard and NPT is also an order option. This configuration has no mounting bracket; brackets are optional. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow from the datasheet and check the 200 size with its G1/8 port against your requirement before you order.
The M in the code means the bowl drain is operated by hand: open it periodically to expel collected water rather than relying on an automatic or differential-pressure drain. If no one is available to drain it regularly, ask us about the automatic-drain version of the same filter regulator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.