verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT

The AirTAC AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$90.99 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT

The GFR400C10AJF2TK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 400 unit is configured with a 3/8 in NPT port, an automatic drain that ejects collected condensate without manual attention, a 40 um standard filter element, an embedded square gauge reading in psi, and a built-in check valve that helps hold downstream pressure if the upstream supply drops. No mounting bracket is included. The regulated outlet is adjustable from 0.15 to 0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the polycarbonate bowl suits ambient temperatures from -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and each size can be ordered with manual or differential-pressure draining, a 5 um element (code W), MPa, psi or bar gauge scales, and PT, G or NPT threads. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application.

AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT Technical Specifications

ModelAirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT Is Used

precision_manufacturing

CNC machining cell air supply

Feeding clean, regulated air to a CNC machining cell's pneumatic clamps and tool-change cylinders, where the 40 um element protects directional valves and the 20-130 psi adjustment covers the cell's actuator settings.

conveyor_belt

Packaging line stopper and pusher actuators

Supplying regulated air to the stoppers, pushers and diverters on a packaging conveyor, where the check valve holds actuator position during upstream pressure dips and the automatic drain handles condensate from a long main run.

factory

Automotive assembly bench air drops

Conditioning the air drop at an automotive assembly bench that runs impact drivers and air cylinders, keeping water and scale out of the tools while the square psi gauge lets operators verify set pressure at a glance.

Is the AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT the Right Unit?

Size 400 with a 3/8 in NPT port sits in the upper-middle of the GFR range; step up to size 600 or down to 300 or 200 as your port and flow requirements dictate, and ask us to check the published flow curve against your consumption before ordering. Drain choice matters: this unit's automatic drain discharges condensate on its own, while manual and differential-pressure versions are the other catalogue options. The 40 um element is the standard grade; specify code W for the 5 um grade where finer particulate capture is needed. The embedded square gauge on this model reads in psi; MPa and bar scales are available and an external round gauge is optional. The thread here is NPT - PT is the standard GFR thread and G is the other order option - and a mounting bracket is available if you need to secure the unit.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your working pressure and air consumption and we will confirm the sizing from the datasheet on request.

The K code fits a reverse-flow check valve so downstream pressure is held if the upstream supply drops, and the A code fits an automatic drain that discharges collected condensate from the bowl without anyone opening it. Both are order options across the GFR family; this unit carries both, along with the square psi gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR400C10AJF2TK Filter Regulator 3/8 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10AJF2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.