The AirTAC GC200C06C2W AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C06C2W is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one filtered-air supply point. This 200-size unit has PT1/8 ports, a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain on the filter bowl, and a fitted round gauge reading in psi. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and the lubricator delivers oil mist downstream to protect air tools and cylinders. Maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC line is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and options include 40 um or 5 um filtration, differential-pressure, automatic or manual drains, gauge style and scale (MPa, psi or bar), a reverse/check valve, and PT, G or NPT threads. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing for your application on request.
| Model | GC200C06C2W AirTAC F.R.L. Combination, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to a compact assembly station where hand tools, air cylinders and small actuators share one 1/8 inch drop, with the 5 um element guarding fine pneumatic components.
Sits at the head of a packaging conveyor's pneumatic circuit, cleaning the air to 5 um, holding a steady working pressure for consistent clamp and pusher strokes, and oil-misting the cylinders that cycle all shift.
Supplies conditioned air to pneumatic clamps on a machining or inspection bench, where the psi gauge lets the operator set and verify clamp pressure and the lubricator keeps the clamp cylinders sealing well.
Choose the size and port step against the air demand of the circuit: 200 is the smallest GC size, here with 1/8 inch PT ports, and larger sizes carry larger ports and more flow. This unit is specified with the 5 um element (code W) instead of the 40 um standard, a differential-pressure drain (the default), and a round psi gauge; a square embedded gauge with MPa, psi or bar scale is the alternative. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application and we will confirm the flow data from the datasheet and check the sizing for you before you order.
The W in the code GC200C06C2W selects the optional 5 um element in place of the 40 um standard, giving finer removal of water and particulate for sensitive downstream components. If your circuit does not need fine filtration, the 40 um standard grade is the lower-restriction choice; we can confirm the right grade for your application on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.