The AirTAC GC200C06F2 AirTAC F.R.L. Combination, PT1/8, psi Gauge is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C06F2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one conditioning set. This configuration is built around PT1/8 ports on the GC200 size, with the filter element at the standard 40 um grade, a differential-pressure drain on the filter bowl, a standard regulator with a square gauge reading in psi, and a mounting bracket included. In use, it takes a single compressed-air feed and delivers cleaned, regulated and lubricated air to downstream equipment.
This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port steps, and with options including 5 um filtration (code W), automatic or manual bowl drains, alternative gauge scales, G (BSPP) or NPT threads, and low-pressure regulation. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet figures for your application on request.
| Model | GC200C06F2 AirTAC F.R.L. Combination, PT1/8, psi Gauge |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds cleaned, regulated and lubricated air to the tool-change cylinders, clamps and purge points of a machining centre, protecting the machine's pneumatic circuits from water and swarf-laden shop air.
Conditions the air feeding carton-sealing and case-packing cylinders on a packaging line, keeping seals lubricated and pressure held steady so stroke speed and holding force stay repeatable through the shift.
Prepares the air supply for a lab automation skid's pick-and-place actuators and air bearings, where the 40 um element, stable regulated pressure and consistent oil mist protect sensitive motion components.
Start with the port step: the GC200 size carries PT1/8 here, and larger sizes (300/400/600) step up in port and flow capacity, so size the unit against the air demand of the machine it feeds. Choose the drain for the filter bowl: differential-pressure (as fitted here, draining on load), automatic for unattended drainage, or manual where controlled draining is preferred. Filtration is 40 um standard or 5 um with the W code; the regulator is standard type here, with a low-pressure L option available; the gauge can be ordered in MPa, psi or bar scales and as an embedded square or external round gauge. Thread is PT as standard, with G (BSPP) and NPT as orderable options, and a bracket is included.
Before ordering, note that AirTAC publishes flow as curves, not a single rated figure. Send us your application's air demand and we will confirm the correct size and datasheet figures on request.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application's air demand and we will confirm the correct size and the datasheet flow figures on request.
This GC200C06F2 has the differential-pressure drain as standard: condensate collected in the filter bowl is discharged automatically when the pressure differential across the element rises. If you prefer, the filter can be ordered with an automatic drain for unattended operation or a manual drain where controlled draining suits the installation.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.