verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8

The AirTAC GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.23 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8

The GC200C06F2G is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-preparation set. This configuration is the GC200 size with a 1/8 in port in G (BSPP) thread, a 40 um standard filter element with a differential-pressure drain on the bowl, a polycarbonate bowl, and a standard regulator with an adjustment range of 0.15-0.9 MPa (20-130 psi). A round external gauge with a psi scale is fitted, no reverse/check valve is included, and a mounting bracket is supplied. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC line is available in sizes 200, 300, 400 and 600 with a choice of ports and threads, 5 um (W) or 40 um filtration, automatic, manual or differential-pressure drains, gauge scales in MPa, psi or bar, and an optional reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8 Technical Specifications

ModelGC200C06F2G AirTAC F.R.L. Combination Unit, G1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8 Is Used

factory

Assembly-line air drops

Point-of-use air preparation at workstations on an automotive assembly line, where each drop needs filtered, regulated and lubricated air for small pneumatic actuators and clamps fed from a 1/8 in connection.

conveyor_belt

Packaging machine supply

Feeding cylinders and air jets on a carton-sealing or labelling conveyor, where the filter removes water and particulate, the regulator holds a steady setting, and the lubricator mists oil for the valve and cylinder seals.

handyman

Maintenance tool stations

A wall-mounted air outlet in a plant maintenance shop serving pneumatic hand tools such as impact wrenches and die grinders, which rely on clean, regulated, oil-misted air to keep running smoothly.

Is the GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8 the Right Station?

Start with the size and port: the GC series steps through sizes 200, 300, 400 and 600, and each size carries a defined port - here the 200 size gives a 1/8 in port, so check the step up if your flow demand is near the top of this frame. Choose the drain for the filter bowl: differential-pressure (as fitted here, the default), automatic (A) for unattended draining, or manual (M). Choose the element grade: 40 um standard or 5 um with the W code. For the gauge, pick the scale - MPa (1), psi (2) or bar (3) - and whether the embedded square gauge or the external round gauge suits your panel. Thread is PT as standard, with G (BSPP) and NPT as coded options; this unit is ordered in G. A reverse/check valve (K) can be specified where backflow protection is needed.

One honest note on sizing: AirTAC publishes flow for this series as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application details and we will confirm the flow and datasheet figures against the curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8 FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a flow number here. Tell us your application and operating pressure and we will confirm the flow and datasheet figures for this unit on request before you order.

This unit is supplied with the differential-pressure drain, the default option, which discharges condensate automatically when the pressure differential across the element rises. If you prefer, the same unit can be ordered with an automatic drain (code A) for continuous unattended draining, or a manual drain (code M) where an operator drains the bowl on a routine.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06F2G AirTAC F.R.L. Combination Unit, G1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06F2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.