The AirTAC GC200C06F2K AirTAC F.R.L. Combination Unit, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC200C06F2K is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one complete air-treatment set. It cleans compressed air (40 um standard element, with a differential-pressure drain that bleeds collected water as flow passes through), regulates downstream pressure across a 0.15-0.9 MPa (20-130 psi) adjustment range, and adds oil-mist lubrication for downstream tools and actuators. This size 200 configuration is ported PT1/8 with a square pressure gauge scaled in psi, a reverse/check valve fitted to hold downstream pressure, and a mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and with options including automatic or manual drains, a 5 um filter element (code W), gauge scale in MPa, psi or bar, and G (BSPP) or NPT threads in place of the PT standard. On this size 200 unit the filter and lubricator bowls are polycarbonate; size 600 units use aluminium alloy bowls. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GC200C06F2K AirTAC F.R.L. Combination Unit, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to the cylinder-driven capping, filling and labelling stations on a beverage bottling line, with the check valve holding the set pressure downstream.
Supplies a workshop drop feeding impact wrenches, air ratchets and blow guns, where the lubricator's oil mist protects the tools and the regulator holds a stable working pressure.
Conditions the air for pneumatic clamps and fixtures on a machining cell, keeping particulate and water out of the clamping valves while holding the clamping pressure set on the psi gauge.
Start with the port and size step: size 200 with a 1/8 inch PT port suits compact circuits, while stepping up to sizes 300, 400 or 600 gives larger ports and higher flow capacity. Choose the drain for the filter: differential-pressure (this model) drains only while air is flowing, automatic drains continuously regardless of flow, and manual drains are emptied by hand. Pick the filter grade - 40 um standard as fitted here, or the 5 um W option where finer particle removal is needed. Select the gauge scale (this unit is psi; MPa and bar are available) and the thread: PT is the standard, with G (BSPP) and NPT as orderable options. A reverse/check valve (fitted here, code K) and a mounting bracket round out the choices. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your application and we will confirm the relevant flow and datasheet figures on request before you order.
K means a reverse (check) valve is fitted to the regulator section, allowing downstream pressure to be held if the upstream supply is lost. Units without the K code have no check valve. The rest of this code decodes as size 200, PT1/8 port, square gauge with psi scale, 40 um filter element and differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.