The AirTAC GC200C06LC2 AirTAC F.R.L. Combination, PT1/8, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C06LC2 is an AirTAC GC three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-preparation set. This configuration is the 200 size with PT1/8 ports, a differential-pressure drain on the filter bowl, the standard 40 um filter element, and a low-pressure regulator type fitted with a round gauge scaled in psi. The mounting bracket is included, so the set can be secured directly to a machine frame or pneumatic panel.
This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with a choice of PT, G or NPT threads, drain types, 40 um or 5 um (W) filter grades, gauge styles and scales, and standard or low-pressure regulator types. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing for your application on request.
| Model | GC200C06LC2 AirTAC F.R.L. Combination, PT1/8, Low-Pressure |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to clamping cylinders on a fixture line, with the low-pressure regulator set to suit light-duty clamping actuators.
Prepares the air feeding diverters, pushers and gripper cylinders on a packaging conveyor, keeping moisture and particles out of the valve manifold.
A complete filter-regulator-lubricator set for bench drops running air tools and small cylinders, with the psi gauge giving a direct readout at the point of use.
Start with the port size: this unit is the 200 frame with PT1/8 ports; step up to 300, 400 or 600 when the line demands larger ports and more flow. Choose the drain to suit access: differential-pressure (as fitted here) for unattended duty, automatic where condensate is heavy, or manual where an operator drains on a schedule. Filter grade is 40 um as standard; specify the W option for 5 um where finer filtration is needed. The gauge here is the round type scaled in psi; embedded square gauges and MPa or bar scales are alternatives. Thread is PT as standard, with G and NPT available to order, and a bracket is included.
Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the correct size and the datasheet flow curve for the GC200C06LC2 on request.
The L in the code marks the low-pressure regulator type, intended for circuits that run below the standard adjustment band; the exact range for this variant is not published, so we confirm it on request. The C2 in the code means the round gauge fitted is scaled in psi, and MPa or bar scales are available as alternatives.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.