verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure

The AirTAC GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.38 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure

GC200C06LC2G is a genuine AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one matched set. This 200-size unit has G1/8 (BSPP) ports, a 40 um filter element, a differential-pressure drain on the filter bowl, the low-pressure regulator type, a round pressure gauge scaled in psi, and a mounting bracket. In use, the filter strips water and particulate from the compressed air, the regulator holds the downstream set pressure, and the lubricator carries an oil mist to the cylinders, valves and air tools fed from this drop. The filter bowl at this size is polycarbonate (PC), and the maximum working (inlet) pressure is 1.0 MPa (145 psi) with an operating temperature of -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series is available in four sizes (200, 300, 400 and 600) with ports from 1/8 to 1 inch, and options that include 5 um filtration (code W), automatic or manual drains, gauge scales in MPa, psi or bar, and G or NPT threads in place of the PT standard. Flow through the combination is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet details for your application before ordering.

GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure Technical Specifications

ModelGC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure Is Used

precision_manufacturing

Pneumatic press circuit

Feeding a pneumatic press or clamping cylinder on a fabrication line: the filter section removes water and pipe swarf before they reach the valve, the low-pressure regulator holds the reduced set pressure the tooling was set up for, and the lubricator mists the cylinder seals through every stroke.

conveyor_belt

Packaging line air drops

A single treated-air drop on a packaging or bottling conveyor: one GC set at the drop conditions the supply for the box-flap cylinders, gripper actuators and stop gates downstream, so each station receives clean, regulated, lubricated air from G1/8 take-offs.

factory

Assembly plant tool stations

A workbench air station in an automotive assembly cell serving impact drivers and air ratchets: the filter keeps moisture and grit out of the tools, the regulator pins the supply at the station's set pressure, and the lubricator keeps the tool motors oiled through a full shift.

Is the GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure the Right Station?

The real choices in this series are the size and port step (200/300/400/600, ports 1/8 to 1 inch), matched to the air your line actually uses; the drain type on the filter (differential-pressure as on this unit, automatic, or manual); the filter grade (40 um standard, 5 um with code W); the gauge (an embedded square gauge as standard, or the external round gauge coded here) and its scale (MPa, psi or bar); the thread (PT is the standard, with G and NPT as order options); and the regulator type, where L marks the low-pressure version. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details - supply pressure, downstream consumption and port size - and we will confirm the sizing from the datasheet on request before you order.

Yes, both are catalogue choices. The embedded square gauge is the standard fitment and an external round gauge (coded C on this unit) is an option, with scales in MPa, psi or bar - the C2 in GC200C06LC2G means a round gauge scaled in psi. Thread is likewise selectable: PT is the standard, with G (BSPP) and NPT available to order; this unit carries G1/8 ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06LC2G AirTAC F.R.L. Combination, G1/8, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06LC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.