The AirTAC GC200C06MC2 AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C06MC2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator working together to deliver clean, regulated, lubricated compressed air. This configuration is size 200 with a PT1/8 (1/8 in) port in PT thread, a 40 um standard filter element and a manual drain on the filter bowl. The regulator is the standard type with a 0.05-0.9 MPa (7-130 psi) adjustment range, and an external round gauge reading in psi is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate, and a mounting bracket is included. No reverse/check valve is fitted.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and with options including automatic or manual drainage, a 5 um filter element (code W), G (BSPP) or NPT threads, gauge scales in MPa, psi or bar, and an embedded square or external round gauge. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GC200C06MC2 AirTAC F.R.L. Combination, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding filtered, regulated and lubricated air to the cylinders and air cylinders of a carton-sealing and stretch-wrapping station, where the manual drain is bled during scheduled changeovers.
Supplying the tool-clamp, chip-door and workholding circuits of a CNC machining centre, where the 40 um element and set regulator pressure protect downstream valves and actuators.
Conditioning the air feeding gripper cylinders and vacuum ejectors on a conveyor-mounted pick-and-place station, with the lubricator providing oil mist for the actuator seals.
Start with the size and port: 200/300/400/600 step up in port and flow capacity, so match the size to the air demand of the machine or line being supplied - this unit takes PT1/8. Choose the drain type: this configuration has a manual drain (code M), which suits points where an operator can bleed the bowl on a routine; automatic (A) and differential-pressure drains are available where the unit is hard to reach. Filter grade is 40 um as standard here; specify the W option for 5 um where finer particulate removal matters. The gauge on this unit is an external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included.
Flow for this series is published as curves, not a single rated number, so we cannot quote a rated flow here. Ask us to confirm sizing against the datasheet curves and your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not state a rated flow, Cv or SCFM number. Tell us your application and operating pressure and we will confirm the flow figures from the datasheet on request before you order.
Yes. The MC2 code here means a manual drain on the filter bowl, which an operator bleeds periodically. The GC series is also available with an automatic drain (code A) or the differential-pressure drain, so choose the drain type that matches how often the installation can be serviced.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.