The AirTAC GC200C06MC2GK AirTAC F.R.L. Combination, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC200C06MC2GK is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-preparation set. This configuration is size 200 with a G1/8 (1/8 in) G-thread port, a 40 um standard filter element, a manual drain on the filter bowl, and a standard regulator with an adjustment range of 0.05-0.9 MPa (7-130 psi). It is fitted with an external round gauge reading in psi and a reverse/check valve, and includes a mounting bracket. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of ports, thread types, drain types, filter grades and gauge scales. Flow is published in the AirTAC catalogue as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.
| Model | GC200C06MC2GK AirTAC F.R.L. Combination, G1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding spray guns and air-assisted applicators on a paint line, where the filter removes water and particulate, the regulator holds a steady set pressure and the lubricator mists oil into the air stream.
Supplying the pneumatic cylinders and actuators on a cartoning or case-packing conveyor, giving the machine clean, regulated and lubricated air at a single preparation point.
Preparing air for the clamping and tool-change circuits of a CNC machining centre, where stable regulated pressure and lubricated air keep the machine's pneumatic valves and cylinders working.
Start with size and port: the 200 size with a 1/8 in port suits smaller air-preparation duties, and stepping up through 300, 400 and 600 increases both port size and flow capacity - match the step against the air demand of the circuit rather than the pipe alone. Choose the drain type where it applies: manual drain (as here) requires periodic draining by hand, while automatic and differential-pressure drains discharge condensate without operator attention. Filter grade is 40 um as standard, with a 5 um element available as the W option. Gauge scale can be MPa, psi or bar, in embedded square or external round form. Thread is PT as standard, with G (BSPP) and NPT available as order options; a bracket is included on this unit. Flow for this family is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves in the catalogue rather than a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your application and we will confirm the flow and datasheet figures for this unit on request.
The M in the code GC200C06MC2GK specifies a manual drain on the filter bowl, so condensate is drained by hand. The GC family is also available with automatic (A) or differential-pressure (blank) drains, and the filter element can be specified as 5 um with the W option instead of the 40 um standard fitted here.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.