verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06MC2K AirTAC F.R.L. Combination, PT1/8

The AirTAC GC200C06MC2K AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.21 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06MC2K AirTAC F.R.L. Combination, PT1/8

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-treatment set. This configuration, GC200C06MC2K, is the size 200 unit with 1/8 in PT ports. The filter element is the standard 40 um grade and the bowl is drained by hand (code M), so an operator empties collected water on a routine rather than automatic basis. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and it carries a round external gauge reading in psi (code C2). A reverse/check valve (code K) is fitted, and the mounting bracket is included. The polycarbonate bowls on the filter and lubricator sections suit this size; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part covering the full GC size range of 200, 300, 400 and 600, with options including automatic or differential-pressure drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, and G (BSPP) or NPT threads in place of the PT standard. Flow figures for this series are published as curves rather than a single rated number, so ask us and we will confirm the datasheet figures for your application on request.

GC200C06MC2K AirTAC F.R.L. Combination, PT1/8 Technical Specifications

ModelGC200C06MC2K AirTAC F.R.L. Combination, PT1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06MC2K AirTAC F.R.L. Combination, PT1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06MC2K AirTAC F.R.L. Combination, PT1/8 Is Used

precision_manufacturing

CNC machine pneumatic clamping

Feeds clean, regulated and lubricated air to the clamping cylinders and fixtures on a CNC machining cell, with the psi gauge letting the setter read the clamp pressure directly and the check valve holding the circuit if supply drops.

conveyor_belt

Packaging line conveyor actuators

Conditions the air feeding the stoppers, pushers and diverters on a carton packaging conveyor: the 40 um element strips water and debris, the regulator holds a steady setting, and the lubricator mists oil for the cylinder seals.

local_shipping

Assembly station air tools

Supplies treated air to impact drivers and nutrunners at a vehicle assembly bench, where the manual-drain bowls suit a station that is drained at shift start and the round psi gauge lets operators verify tool supply pressure.

Is the GC200C06MC2K AirTAC F.R.L. Combination, PT1/8 the Right Station?

Start with the size and port: the GC series steps through sizes 200, 300, 400 and 600, and the port code here (06) gives 1/8 in PT threading - step up a size if your line's flow demand points to a larger port. Choose the drain to match maintenance habits: manual (this unit, code M) needs someone to drain the bowl, while automatic and differential-pressure drains handle it without attention. The filter grade is 40 um as standard; specify code W if the application needs 5 um filtration. Gauge options are the embedded square gauge or the external round gauge fitted here (code C), with scales in MPa (1), psi (2, this unit) or bar (3). Thread is PT as standard, with G (BSPP) and NPT available as ordered options; a reverse/check valve is ordered with code K, and the bracket is included on this unit. One honest note on sizing: flow for this series is published as curves, not a single rating, so send us your application details and we will confirm the right size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06MC2K AirTAC F.R.L. Combination, PT1/8 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure for this unit. Send us your application - the tools or actuators it feeds and your supply pressure - and we will confirm the datasheet flow figures and check the size 200 / 1/8 in port against your demand before you order.

The M in the code means the filter bowl is drained by hand: an operator opens the drain on a routine basis to empty collected water. If you would rather not rely on that, the same GC size is available with an automatic drain (code A) or a differential-pressure drain (blank), which handle drainage without operator attention - just tell us which suits your maintenance routine when ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06MC2K AirTAC F.R.L. Combination, PT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MC2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.