The AirTAC GC200C06MC2W AirTAC F.R.L. Combination, PT1/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC200C06MC2W is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. It cleans compressed air of water and particulate down to 5 um, holds a stable downstream pressure adjustable from 0.05 to 0.9 MPa (7-130 psi), and adds a fine oil mist to extend the life of downstream air tools and cylinders. This 200-size unit is threaded PT1/8, carries a 5 um filter element (the finer of the two catalogue grades), a manual drain on the filter bowl, a round pressure gauge reading in psi, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauge styles and scales, and G or NPT thread options to order. Flow is published as curves rather than a single rating, so ask us to confirm sizing and any datasheet figure against your application before ordering.
| Model | GC200C06MC2W AirTAC F.R.L. Combination, PT1/8, 5 um |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding clean, regulated and lubricated air to the tool-changer and clamping cylinders on a machining centre, where the 5 um element protects fine pilot valves from particulate and the regulator holds a steady setting.
Conditioning the air that drives pick-and-place and sealing cylinders on a packaging conveyor, with the lubricator misting oil to keep cylinder seals and guide surfaces working smoothly shift after shift.
A point-of-use F.R.L. at an assembly bench, giving each operator station its own 5 um filtered, pressure-adjusted and lubricated supply independent of the main header.
Start with the port step: the 200 size here is the smallest in the GC range (PT1/8), so match it to the line size and the flow your circuit actually needs - larger sizes 300/400/600 carry larger ports and more flow. Choose the drain: this unit has a manual drain, which means someone drains the bowl on a routine; an automatic or differential-pressure drain removes that task where the unit is hard to reach. Choose the filter grade: 40 um is the standard element and 5 um (this unit, code W) suits finer protection downstream. Pick the gauge scale (MPa, psi or bar) and style, and the thread: PT is the standard here, with G (BSPP) and NPT available as order options. A bracket is included; a reverse/check valve is not fitted on this code.
One honest note before you order: AirTAC publishes flow as curves, not as a single rated figure, so we do not quote a flow number here. Send us your application and we will confirm sizing from the datasheet on request.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not state a flow number. Send us your line size and application and we will confirm the sizing from the datasheet on request before you order.
The M in the code means the filter bowl has a manual drain: accumulated water is released by hand on a routine you set. If the unit will be mounted where routine access is difficult, ask about the same GC configuration with an automatic or differential-pressure drain instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.