verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um

The AirTAC GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.88 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one supply unit. This configuration, the GC200C06MF2W, is the 200 size with a 1/8 in PT port. The filter stage carries the 5 um element (code W) for finer water and particulate removal than the 40 um standard, with a manual drain you open by hand to purge collected condensate. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi) and a square gauge fitted, reading in psi; an external round gauge is optional. The bowl on this unit is metal, and a mounting bracket is included.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600, with port sizes stepping up from 1/8 in to 1 in, and with choices of drain type, filter grade, gauge scale (MPa, psi or bar), thread (PT standard, G and NPT as order options) and bracket. Maximum working inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um Technical Specifications

ModelGC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um Is Used

factory

Point-of-use supply on a packaging line

Feeding a small packaging machine's air manifold, this unit filters the shop air to 5 um, holds a steady regulated pressure for the sealing and clamp cylinders, and meters oil mist to keep them running smoothly.

conveyor_belt

Air prep for conveyor diverters and stoppers

On a conveyor section with pneumatic diverters, stoppers and lifters, the combination cleans the supply, regulates it to the actuator's set pressure and lubricates the valves and cylinders that cycle all shift.

handyman

Workshop bench supply for air tools

At a maintenance bench or assembly station, the unit conditions the drop-line feed: fine filtration and moisture drainage ahead of the regulator, a psi gauge for setting tool pressure, and oil mist for lubricated air tools.

Is the GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um the Right Station?

Start with the size and port: 200 is the smallest GC frame, and the 1/8 in PT port here suits compact supply points - step up to 300, 400 or 600 when the line's flow demand calls for a larger frame. Choose the drain to match attendance: manual (as fitted here) means an operator opens it periodically; automatic and differential-pressure drains are available on other codes if the unit sits where manual purging is impractical. The 5 um element (W) is the finer choice over the 40 um standard where downstream valves and cylinders need cleaner air. Gauge scale is selectable - this code carries the embedded square gauge reading psi, with MPa or bar scales and an external round gauge as options. Thread is PT as standard; G (BSPP) and NPT are order options. A bracket is included on this code.

One honest note before you order: AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a flow number here. Send us your application details and we will confirm the sizing against the datasheet before you commit.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a flow number for this unit. Tell us your application - the actuators, their cycle rate and your available supply pressure - and we will confirm the flow and sizing from the datasheet on request before you order.

The M in the code specifies a manual drain: an operator opens it periodically to purge the condensate collected in the filter bowl. If the unit will be mounted where manual purging is impractical, other GC codes are available with an automatic drain or the default differential-pressure drain - just ask for the variant that suits the installation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06MF2W AirTAC F.R.L. Combination, PT1/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.