verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8

The AirTAC GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.22 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one air-preparation set, so the downstream equipment receives air that is filtered of water and particulate, held at a set pressure and lubricated. This GC200C06MF2WK is the 200 size with PT1/8 (1/8 in) ports. It is built with the 5 um filter element (in place of the 40 um standard), a manual drain on the filter bowl, an embedded square gauge reading in psi, a reverse/check valve fitted on the regulator, and a mounting bracket included. The standard regulator on this unit adjusts from 0.05 to 0.9 MPa (7-130 psi), and maximum inlet pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC combination is available in the 200, 300, 400 and 600 sizes with a choice of ports, drain types, filter grades, gauge styles and scales, and G (BSPP) or NPT threads as order options alongside the standard PT. Flow is published by AirTAC as curves rather than a single rated figure, so ask us and we will confirm the flow and datasheet figures for this exact model against your application.

GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8 Technical Specifications

ModelGC200C06MF2WK AirTAC F.R.L. Combination, PT1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8 Is Used

precision_manufacturing

CNC machining cell air supply

Feeding the pneumatic actuators, clamps and tool-change cylinders on a CNC machining cell: the filter stage strips water and fine particles, the regulator holds a steady set pressure, and the lubricator mists oil to the air tools downstream.

conveyor_belt

Packaging and conveyor line cylinders

Supplying the pick-and-place cylinders, diverters and stopper gates along a packaging or conveyor line, where filtered, regulated and lubricated air keeps the small-bore cylinders cycling cleanly at a stable pressure.

air

Paint-spray booth air feed

Conditioning the air line to spray guns and air-assisted applicators in a paint shop, where the 5 um element reduces fine particles, the regulator pins the gun supply pressure and the lubricator is set per the gun manufacturer's air requirement.

Is the GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8 the Right Station?

Start with the size and port: the 200 size here carries PT1/8 (1/8 in) ports, and the step up through 300, 400 and 600 brings larger ports and more flow capacity, so match the size to the air demand of the machines downstream. Choose the drain type where it applies: manual drain (as fitted here) means someone drains the bowl on a routine, differential-pressure drain handles it automatically as flow passes, and automatic drain ejects condensate on its own. Filter grade is a real choice: 40 um is the standard element and 5 um (the W option, fitted here) suits finer-particle sensitive equipment. Gauge style and scale are selectable: embedded square gauge standard, external round gauge optional, with MPa, psi or bar scales. Thread is PT as standard with G (BSPP) and NPT as catalogue options, and a bracket is included on this unit. One honest note on sizing: AirTAC publishes flow as curves, not a single rated number, so send us your application and we will confirm the right size before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8 FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application and line pressure and we will confirm the flow and datasheet figures for this exact model on request before you order.

The M in the code GC200C06MF2WK specifies a manual drain on the filter bowl: condensate is emptied by hand on a routine. If you would rather not rely on manual draining, the same 200-size combination can be ordered with a differential-pressure drain (the default) or an automatic drain - just ask and we will quote the matching code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06MF2WK AirTAC F.R.L. Combination, PT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MF2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.