The AirTAC GC200C06MLC2K AirTAC F.R.L. Combination PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one ordered set. This unit, GC200C06MLC2K, is the size 200 frame with 1/8 in PT ports. It carries a manual drain on the filter bowl, the standard 40 um filter element, a low-pressure type regulator, a round pressure gauge reading in psi, a reverse/check valve, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The bowls on this configuration are metal.
This is a genuine AirTAC part. The GC range spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and each position of the code selects drain type, filter grade, regulator type, gauge style and scale, check valve and thread (PT standard; G and NPT available to order). Rated flow is published as curves rather than a single figure, so ask us to confirm flow and datasheet details for your application before ordering.
| Model | GC200C06MLC2K AirTAC F.R.L. Combination PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding a small air cylinder on an assembly bench: the filter strips water and particles, the low-pressure regulator holds the setpoint the tool was set up with, and the lubricator mists oil to the cylinder seals.
Supplying sealing-jaw cylinders on a packaging machine, where the reverse/check valve guards the circuit against backflow and the manual drain lets an operator bleed accumulated water at shift start.
Conditioning air to grippers and small actuators on a laboratory automation rig, with the round psi gauge giving a direct local reading during set-up and the 40 um element protecting fine valve components.
Size 200 with 1/8 in PT ports is the entry step of the GC range; step up through sizes 300, 400 and 600 when the circuit needs larger ports and more flow. The manual drain here means someone opens the drain at the filter bowl; an automatic drain (code A) or the default differential-pressure drain can be ordered instead. The 40 um element is standard; specify W for the 5 um grade. The gauge on this unit is the external round type reading in psi; embedded square gauges and MPa or bar scales are alternatives. Thread is PT as standard, with G (BSPP) and NPT as orderable options; a bracket is included and the K code adds the reverse/check valve. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and datasheet figures for GC200C06MLC2K on request before you order.
The L in the code marks the low-pressure type regulator. Standard GC units with a manual drain adjust across 0.05-0.9 MPa (7-130 psi); the exact adjustment range for this low-pressure variant is not published in our material, so confirm your working setpoint with us and we will verify it against the datasheet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.