The AirTAC GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled into one supply unit. This GC200C06MLC2WGK is built on the 200 size with a G1/8 (BSPP) port. It carries the W 5 um filter element, a manual drain on the filter bowl, the low-pressure regulator type, a round pressure gauge reading in psi, and a reverse (check) valve; the bowl on the filter section is metal and a mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
It is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options for drain type, 40 um or 5 um filtration, gauge style and scale, PT, G or NPT threads, and a reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application on request.
| Model | GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Installed at the drop feeding an assembly cell, the unit filters water and particles down to 5 um, holds the set supply pressure for the cell, and mists oil into the air driving cylinders, grippers and pneumatic screwdrivers.
Mounted at the supply to a bottling conveyor's pneumatic section, it cleans the compressed air, keeps the regulator setting stable for stopper and pusher cylinders, and lubricates the air so valve spools and cylinder seals last longer.
On a clamping fixture circuit in a machine shop, the combination delivers clean, regulated, lubricated air to swing clamps and vises, while the fitted check valve guards against backflow and the psi gauge gives the operator a direct reading.
Choose the size by port and flow: 200 is the compact step with a 1/8 in port here, while 300, 400 and 600 step up in port and capacity. The filter drain is a real choice - manual (coded M on this unit), automatic, or differential-pressure - with manual suiting points where an operator can bleed the bowl. Filter grade is 40 um standard or 5 um with W; this unit takes the finer 5 um element, the better match for downstream valves and cylinders. Gauges are the embedded square type or an optional external round gauge in MPa, psi or bar scales; this code carries a round psi gauge. Thread is PT as standard with G (BSPP) and NPT as orderable options - this unit is G-threaded. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for this exact configuration on request.
The M in the code selects a manual drain: an operator opens the drain to bleed collected water from the filter bowl. If the installation runs unattended, the same GC200 unit can be ordered with an automatic or differential-pressure drain instead - just ask and we will decode the right variant.