verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8

The AirTAC GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.88 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled into one supply unit. This GC200C06MLC2WGK is built on the 200 size with a G1/8 (BSPP) port. It carries the W 5 um filter element, a manual drain on the filter bowl, the low-pressure regulator type, a round pressure gauge reading in psi, and a reverse (check) valve; the bowl on the filter section is metal and a mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

It is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options for drain type, 40 um or 5 um filtration, gauge style and scale, PT, G or NPT threads, and a reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application on request.

GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 Technical Specifications

ModelGC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 Is Used

factory

Assembly-cell air preparation

Installed at the drop feeding an assembly cell, the unit filters water and particles down to 5 um, holds the set supply pressure for the cell, and mists oil into the air driving cylinders, grippers and pneumatic screwdrivers.

conveyor_belt

Bottling line conveyor control

Mounted at the supply to a bottling conveyor's pneumatic section, it cleans the compressed air, keeps the regulator setting stable for stopper and pusher cylinders, and lubricates the air so valve spools and cylinder seals last longer.

engineering

Machine shop fixture clamping

On a clamping fixture circuit in a machine shop, the combination delivers clean, regulated, lubricated air to swing clamps and vises, while the fitted check valve guards against backflow and the psi gauge gives the operator a direct reading.

Is the GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 the Right Station?

Choose the size by port and flow: 200 is the compact step with a 1/8 in port here, while 300, 400 and 600 step up in port and capacity. The filter drain is a real choice - manual (coded M on this unit), automatic, or differential-pressure - with manual suiting points where an operator can bleed the bowl. Filter grade is 40 um standard or 5 um with W; this unit takes the finer 5 um element, the better match for downstream valves and cylinders. Gauges are the embedded square type or an optional external round gauge in MPa, psi or bar scales; this code carries a round psi gauge. Thread is PT as standard with G (BSPP) and NPT as orderable options - this unit is G-threaded. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for this exact configuration on request.

The M in the code selects a manual drain: an operator opens the drain to bleed collected water from the filter bowl. If the installation runs unattended, the same GC200 unit can be ordered with an automatic or differential-pressure drain instead - just ask and we will decode the right variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06MLC2WGK AirTAC Three-Unit F.R.L., G1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MLC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.