The AirTAC GC200C06MLC2WK AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator set up as one air-preparation station. This configuration, GC200C06MLC2WK, is the GC200 size with PT1/8 ports. It carries the W-grade 5 um filter element for finer water and particulate removal than the standard 40 um element, a manual drain on the filter bowl, a low-pressure-type regulator, a fitted round gauge scaled in psi, a reverse/check valve, and the mounting bracket is included. The medium is compressed air only, with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC200 size is also available with other port sizes, thread options (PT standard, with G and NPT as catalogue options), 40 um or 5 um filtration, differential-pressure, automatic or manual draining, gauge choices and scale options. Because flow for this series is published as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request.
| Model | GC200C06MLC2WK AirTAC F.R.L. Combination, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
A bench-top pneumatic press or clamping fixture needs clean, regulated and lubricated air at the machine inlet. This three-unit combination filters water and particles down to 5 um, holds the working pressure the press was set up for, and mists oil to keep its cylinders sealing well, with the check valve holding the circuit if supply dips.
Packaging machines with small air cylinders for flap folding and tape tacking run continuously and suffer from moisture carryover. Feeding the machine through this GC200 station removes condensate and fine dirt, keeps supply pressure steady through each machine cycle, and delivers oil mist to the cylinders, with manual draining done at shift checks.
A maintenance or assembly bench running impact drivers, ratchets and air screwdrivers needs all three treatments at once: filtration to keep grit out of the tools, a regulator to cap the pressure the tools see, and lubrication to protect their internal vanes and bearings. This single GC200 station supplies the whole bench from one 1/8 in connection.
Start with the size and port: the GC200 step here is the compact end of the range, and stepping up through GC300, GC400 and GC600 gives larger ports and more flow, so match the size to the air demand of the downstream cylinders or tools rather than only to the pipe thread. This unit already carries the 5 um (W) element; the standard 40 um element is the alternative if finer filtration is not required. Draining is manual here, which means someone bleeds the bowl on a routine; the automatic or differential-pressure drain options remove that task where access is awkward. The regulator in this code is the low-pressure type, so if your line runs at ordinary working pressures, check the standard-type variant instead. The fitted round gauge is scaled in psi; MPa and bar scales and an embedded square gauge are the other gauge choices. Thread is PT as standard, with G (BSPP) and NPT available to order, and the bracket is included.
One honest note on sizing: AirTAC publishes flow for this series as curves, not as a single rated number, so we do not quote a flow figure here. Ask us to confirm the flow and datasheet figures against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a flow number for this unit. Tell us your working pressure and the air demand of the equipment downstream, and we will confirm the flow and datasheet figures for this exact model on request before you order.
The W in the code GC200C06MLC2WK selects the optional 5 um filter element instead of the standard 40 um element, which suits applications where finer dirt and water removal protects sensitive valves and cylinders. The M selects a manual drain, so condensate in the filter bowl is released by hand at routine intervals; if you would rather not do that, the same unit is available with an automatic or differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.