The AirTAC GC200C06MLF2GK AirTAC F.R.L. Combination, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-treatment set. This GC200C06MLF2GK is the 200 size with a G1/8 (BSPP) port, a manual-drain filter bowl with 40 um filtration, a low-pressure-type regulator fitted with an embedded square gauge scaled in psi, and a reverse (check) valve. A mounting bracket is included. The polycarbonate bowl lets you see the water and particulate level at a glance, and the manual drain is emptied by hand. The set treats compressed air only, with a maximum inlet pressure of 1.0 MPa (145 psi) and a working temperature of -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC family is published in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, gauge scale options in MPa, psi or bar, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GC200C06MLF2GK AirTAC F.R.L. Combination, G1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding clamp cylinders and swing clamps on a machining centre fixture, where the filter clears line water and chips-laden condensate, the regulator holds a steady low clamp pressure and the lubricator keeps the cylinder seals working smoothly.
Supplying the tape-head and flap-tuck cylinders on a carton sealing line, with the manual-drain bowl emptied at shift start, the psi gauge giving operators a visible setpoint and the check valve holding downstream pressure if the supply dips.
Conditioning shop air ahead of spray guns in a finishing booth: the 40 um filter removes water and particulate that would spoil the finish, the low-pressure regulator sets gun supply pressure, and the lubricator is isolated or filled as the gun manufacturer requires.
Step through the 200/300/400/600 sizes to match the port and flow your line needs; the 200 size carries the 1/8 in port in this configuration. Choose the drain: differential-pressure (the default), automatic (A) or manual (M, as here). Filtration is 40 um standard; specify W for 5 um where finer particulate capture matters. The regulator in this unit is the low-pressure type; its exact adjustment range is not published, so confirm it with us before ordering. The embedded square gauge is standard (psi scale here), an external round gauge is optional, and scales are available in MPa, psi or bar. Thread: PT is the standard; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote one number. Send us your application details and we will confirm the datasheet flow figures and check that the 200 size with its 1/8 in port is correctly sized before you order.
Code M means the filter bowl is drained by hand: open the drain at the bottom of the bowl to release collected water. The same family is also available with the differential-pressure drain (the default, no code) or the automatic drain (code A) if you would rather not drain manually.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.