verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8

The AirTAC GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.38 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one air-treatment set. This configuration, GC200C06MLF2WK, is the size 200 unit with a PT1/8 (1/8 in) port. It carries a 5 um filter element (the finer of the two catalogue grades), a manual drain on the filter bowl, a low-pressure type regulator, an embedded square gauge scaled in psi, and a reverse/check valve fitted upstream of the regulator. A mounting bracket is included, and the metal bowl protects the filter stage in service.

This is a genuine AirTAC part. The GC family is published in sizes 200, 300, 400 and 600, with port sizes stepping up from 1/8 in to 1 in, a choice of 40 um standard or 5 um fine filtration, manual, automatic or differential-pressure drains, gauge scales in MPa, psi or bar, and PT, G or NPT threads. Flow figures for this series are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.

GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8 Technical Specifications

ModelGC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8 Is Used

factory

Small packaging machine air preparation

Feeding the cylinders and air jets on a compact cartoning or wrapping machine, where one set filters the supply, holds a low regulated pressure and carries oil mist to the actuators from a single 1/8 in take-off.

science

Laboratory fixture and test-rig supply

Conditioning air for bench-top test fixtures and clamping rigs that need clean, finely filtered (5 um) air at a low, stable setting, with the psi gauge giving a direct local reading at the rig.

handyman

Workshop air drop for hand-held tools

Mounted on the bracket at an individual workshop air drop, filtering the line, regulating it down for impact drivers and air ratchets, and lubricating the tools in the same pass through the three units.

Is the GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8 the Right Station?

Start with the port step: size 200 with a PT1/8 port is the smallest entry in the GC range, so match it against the air consumption of the machine it feeds and step up to 300, 400 or 600 if the circuit draws more. Because flow for this series is published as curves and not as a single rated figure, ask us to confirm sizing against your application before ordering. This unit is already configured with the 5 um fine element rather than the 40 um standard, a manual drain, a square psi gauge, a low-pressure type regulator and a fitted check valve, so the remaining decodable choices are thread (PT is the standard; G and NPT are catalogue options to order) and bracket mounting, which is included here. Note that this is the low-pressure regulator type; its exact adjustment range is not published in the material we hold, so confirm the setting you need with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Send us your application details and we will confirm the datasheet flow figures and check the size 200 / PT1/8 port against your air consumption before you order.

The manual drain means someone opens the drain on the filter bowl periodically to release collected water rather than relying on an automatic or differential-pressure drain, so it suits attended installations. The 5 um element is the finer of the two catalogue grades (40 um is the standard), fitted here for downstream equipment that needs cleaner air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C06MLF2WK AirTAC F.R.L. Combination, PT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MLF2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.