The AirTAC GC200C08F2 AirTAC F.R.L. Combination Unit, PT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C08F2 is an AirTAC GC-series three-unit F.R.L. combination that filters, regulates and lubricates compressed air using three separate units assembled as one set. This 200-size configuration has a PT1/4 (1/4 in) port, a 40 um filter element with a differential-pressure drain, a standard regulator adjustable from 0.15-0.9 MPa (20-130 psi) with an embedded square gauge scaled in psi, and an oil-mist lubricator. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and options include a 5 um filter element (code W), automatic or manual drains, alternative gauge scales (MPa/psi/bar), and G (BSPP) or NPT thread versions. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details for your application.
| Model | GC200C08F2 AirTAC F.R.L. Combination Unit, PT1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding filtered, regulated and lubricated air to the pneumatic impact wrenches, air ratchets and clamping fixtures along an automotive assembly line, with the regulator set to the tool circuit's working pressure and the lubricator supplying oil mist to keep air tools running smoothly.
Supplying the pneumatic clamps, vises and tool-changer cylinders on a CNC machining centre, where the 40 um filter removes water and pipe scale, the regulator holds a steady clamp pressure, and the lubricator mists oil into the actuator air supply.
Conditioning the air feeding the pusher, divert and sealing cylinders on a carton packaging conveyor, so the differential-pressure drain clears condensed water continuously in service and the regulator keeps cycle pressure consistent across the shift.
Start with the size and port step: 200/300/400/600 correspond to increasing port sizes (here PT1/4) and increasing flow capacity, so match the step to the air demand of the machine or line. Choose the drain type for the filter bowl: differential-pressure (the default, as on this unit), automatic for unattended draining, or manual where an operator drains on a schedule. Choose the filter grade: 40 um standard, or 5 um (code W) where finer particulate removal is needed. Select the gauge scale (MPa, psi or bar) and thread style: PT is the standard, with G (BSPP) and NPT available as order options. A mounting bracket is included.
Flow is published as curves rather than a single rated figure, so before ordering ask us to confirm sizing of this GC200C08F2 against your actual air consumption.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or l/min number for this unit. Tell us your required port size and air consumption and we will confirm the flow and sizing from the datasheet on request before you order.
F2 means the unit is fitted with an embedded square gauge scaled in psi (MPa and bar scales are available as alternatives). This configuration has the default differential-pressure drain on the filter bowl, which drains condensate automatically as the pressure differential rises; automatic (code A) and manual (code M) drain versions can be ordered instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.