The AirTAC GC200C08F2G AirTAC F.R.L. Combination Unit, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one unit, so a single connection point cleans the air, holds a set downstream pressure and adds lubricating mist for the tools and cylinders fed from it. This GC200C08F2G is the size 200 unit with a 1/4 in port in G (BSPP) thread, the standard 40 um filter element, differential-pressure drainage on the filter bowl, a standard regulator covering 0.15-0.9 MPa (20-130 psi), a fitted square gauge reading in psi, and a mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with matching port sizes, and can be ordered with a 5 um filter element (code W), automatic or manual drainage, different gauge scales (MPa, psi or bar), a reverse/check valve, and PT, G or NPT threads. Flow is published in the catalogue as curves rather than a single rated figure, so ask us to confirm flow or any datasheet figure for your application before ordering.
| Model | GC200C08F2G AirTAC F.R.L. Combination Unit, G1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds the pneumatic clamps and tool-change cylinders on a machining centre: the filter removes water and swarf-carrying particles, the regulator holds a steady clamp pressure, and the lubricator mists the cylinder seals.
Mounted at the drop of a packaging conveyor's air supply, the unit conditions air for gripper and pusher cylinders all shift long, with the psi gauge letting operators verify set pressure at a glance.
A workbench drop on an assembly line feeding air tools and small actuators: one GC unit gives each station its own filtered, regulated and lubricated supply instead of relying on the shared header.
Start with the size and port: 200 is the smallest step in the GC range and carries a 1/4 in port here, so match it to the line size and the air demand of the equipment downstream - larger sizes (300/400/600) move more air. Then fix the three decodable choices this code already makes: differential-pressure drainage (the default, which bleeds condensate as flow passes the filter), the standard 40 um element (choose W for 5 um where finer filtration is needed), and the square gauge with a psi scale (MPa and bar scales are also available). Thread options are PT as the catalogue standard with G and NPT as orderable variants - this unit is the G-thread version.
One honest note on sizing: AirTAC publishes filter-regulator-lubricator flow as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application's air demand and we will confirm the correct size from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as performance curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the correct size and the flow figures from the datasheet on request.
Differential-pressure drainage is the default drain on the GC filter: it discharges collected condensate automatically as airflow passes the element, with no operator action. If your application prefers it, the same unit can be ordered with an automatic drain (code A) or a manual drain (code M); note that the regulation range differs by drain type, with manual-drain versions starting from 0.05 MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.