verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4

The AirTAC GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.30 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4

The GC200C08F2WG is a three-piece AirTAC F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This configuration is size 200 with G1/4 ports, fitted with a 5 um filter element (the finer of the two published grades) and a differential-pressure drain that bleeds collected water automatically as flow passes through. The standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) and carries an embedded square gauge reading in psi, so downstream pressure is visible and settable at the wall of the unit. The maximum working (inlet) pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). For size 200 the polycarbonate bowl keeps the water and oil level in view; a mounting bracket is included.

This is a genuine AirTAC part. The GC family is published in sizes 200, 300, 400 and 600, with port sizes from 1/8 to 1 inch, a choice of 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual drains, gauge scales in MPa, psi or bar, and PT (standard), G or NPT threads. Flow for this series is published as curves rather than a single rated figure; ask us and we will confirm the datasheet and sizing figures for your application on request.

GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4 Technical Specifications

ModelGC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4 Is Used

precision_manufacturing

CNC machining cell air supply

Feeds filtered, regulated and lubricated air to the pneumatic clamps, tool-change actuators and chip-blow nozzles on a CNC machining centre, with the 5 um element protecting fine pilot valves from particulate carryover.

handyman

Maintenance-shop impact tool station

A wall-mounted drop at a plant maintenance bay serving impact wrenches and air ratchets: the regulator sets tool working pressure, the lubricator carries oil mist to the tools, and the psi gauge lets technicians set and check the line at a glance.

conveyor_belt

Packaging-line stopper and pusher cylinders

Prepares air for the stoppers, pushers and diverters along a bottling or cartoning conveyor, where the differential-pressure drain sheds condensed water in service and the regulator holds a steady pressure for consistent cylinder stroke timing.

Is the GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4 the Right Station?

Start with the port and size step: 200 is the smallest GC frame, and the 1/4 in port here suits compact supply drops - step up to 300, 400 or 600 if the line's air demand is larger. This unit already carries the finer 5 um element (code W); the alternative is the 40 um standard grade, which suits coarser general-purpose protection. Drain choice matters: this one is differential-pressure (default), while automatic (A) drains unaided and manual (M) drains are emptied by hand. The embedded square gauge reads psi; MPa and bar scales and an external round gauge are alternatives. Thread is G here - PT is the standard offering and NPT is also an order option - and a bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Send us your line pressure, downstream demand and allowable pressure drop, and we will confirm the datasheet curves and correct sizing for your application on request.

The W in the code GC200C08F2WG selects the optional 5 um filter grade; the catalogue default is 40 um. The 5 um element removes finer particulate for downstream pilot valves and precision actuators, while 40 um suits general-purpose protection. Both grades are available across the GC range, and the differential-pressure drain and psi square gauge on this unit are unchanged by the grade choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08F2WG AirTAC F.R.L. Combination Unit, G1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08F2WG and will confirm price, stock and lead time — usually within 7-8 hours.