verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08F2WGK AirTAC F.R.L. Combination, G1/4

The AirTAC GC200C08F2WGK AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.65 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08F2WGK AirTAC F.R.L. Combination, G1/4

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator mounted together to condition compressed air at one station. This GC200C08F2WGK is the size-200 body with G1/4 (BSPP) threads, carrying the 5 um filter element (code W) for finer water and particulate removal than the 40 um standard, a differential-pressure drain, and a reverse/check valve fitted to hold downstream pressure if the supply drops. The regulator is the standard type with an embedded square gauge reading in psi, the filter bowl at this size is PC (polycarbonate), maximum inlet pressure is 1.0 MPa (145 psi), and the medium is compressed air in a non-freezing -5 to 70 C environment. A mounting bracket is included.

This is a genuine AirTAC part. The GC range spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and units can be ordered with manual or automatic draining, the 40 um or 5 um element, MPa, psi or bar gauge scales, G or NPT threads in place of the PT standard, and with or without the reverse/check valve. Regulator adjustment on this configuration covers 0.15-0.9 MPa (20-130 psi). Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet numbers for your application before ordering.

GC200C08F2WGK AirTAC F.R.L. Combination, G1/4 Technical Specifications

ModelGC200C08F2WGK AirTAC F.R.L. Combination, G1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08F2WGK AirTAC F.R.L. Combination, G1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08F2WGK AirTAC F.R.L. Combination, G1/4 Is Used

precision_manufacturing

CNC machining cell air supply

Feeding filtered, regulated and lubricated air to the tool changers, clamps and actuators on a CNC machining centre, with the 5 um element protecting fine-control valves from water and particulate carryover and the check valve holding settings through supply dips.

conveyor_belt

Bottling line conveyor actuators

Supplying the stopper gates, pushers and diverters along a bottling or packaging conveyor, where the lubricator keeps cylinder seals moving smoothly through long shift cycles and the regulator holds a steady setting despite plant pressure swings.

build

Furniture plant nailing and stapling stations

Conditioning shop air ahead of pneumatic nailers and staplers at a furniture assembly bench: the filter strips water and chips, the regulator pins tool pressure to the setting, and the oil mist keeps tool seals and vanes lubricated through the shift.

Is the GC200C08F2WGK AirTAC F.R.L. Combination, G1/4 the Right Station?

Start with the port and size: the 200 body with G1/4 threads suits lines built around 1/4 in piping, while the 300, 400 and 600 bodies step up in port and flow capacity - match the step to the air your application consumes, not to the port alone. Choose the drain: differential-pressure (as fitted here) bleeds the bowl automatically as the pressure differential builds, automatic (A) drains continuously without attention, and manual (M) needs a periodic twist of the drain screw. Choose the element: 40 um is the catalogue standard for general plant air, 5 um (W, as here) for finer protection of sensitive valves and instruments. Gauges are the embedded square type with MPa, psi or bar scales, and an external round gauge is optional. Threads can be ordered in PT (the standard), G or NPT; brackets are optional on the individual units. Flow is published as curves, not a single rating, so send us your air demand and working pressure and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08F2WGK AirTAC F.R.L. Combination, G1/4 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your air demand and working pressure and we will confirm the datasheet curve for this size-200, G1/4 combination before you order.

This unit carries the W-code 5 um element, which removes water and particulate more finely than the 40 um catalogue standard. Choose 5 um where downstream valves, cylinders or instruments are sensitive to fine contamination; the 40 um grade remains the default for general plant air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08F2WGK AirTAC F.R.L. Combination, G1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08F2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.