The AirTAC GC200C08F2WK AirTAC F.R.L. Combination Unit 1/4 in PT is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled into one supply unit. This GC200C08F2WK is built on the 200 size with a 1/4 in PT port. The filter carries the fine 5 um element (code W) with a differential-pressure drain, the standard regulator covers 0.15-0.9 MPa (20-130 psi), and the unit comes with an embedded square gauge scaled in psi, a reverse (check) valve and a mounting bracket. The filter and lubricator bowls on this 200 size are polycarbonate (PC); only the 600 size uses an aluminium alloy bowl.
It is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, and options including automatic or manual drains, the 40 um standard element, gauge scales in MPa, psi or bar, and G or NPT thread variants. Rated flow is published as curves rather than a single figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC200C08F2WK AirTAC F.R.L. Combination Unit 1/4 in PT |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Supplying pneumatic clamps and workholding cylinders on a machining centre, where the filter clears water and chips-laden particulate, the regulator holds a steady clamp pressure and the lubricator keeps the cylinder seals running smoothly.
Feeding the pick-and-place and box-closing cylinders on a carton packing line, giving the machine one filtered, regulated and lubricated air drop instead of three separate components at each station.
Feeding impact wrenches, nutrunners and air ratchets at a bench assembly station, where the oil-mist lubricator extends tool life and the regulator lets each station set its own working pressure.
Within the GC line the real, decodable choices are: size and port (200 with 1/4 in here; sizes 300, 400 and 600 step up toward 3/4 in and 1 in for larger supply), drain type (differential-pressure as fitted here, or automatic or manual), filter grade (the 5 um W element here, or the 40 um standard), gauge scale (psi here; MPa or bar available), and thread (PT is the standard; G and NPT are catalogue options to order). This code also carries the reverse (check) valve and includes the mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Because flow is published as curves rather than a single rating, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your required flow and working pressure and we will confirm the datasheet curve figures for this exact unit on request before you order.
The W in the code GC200C08F2WK selects the optional 5 um element; the catalogue standard for the GC filter is 40 um. The finer 5 um grade removes smaller particulate upstream of the regulator and lubricator, which suits sensitive valves and cylinders. If your application does not need it, the 40 um standard grade is the usual choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.