The AirTAC GC200C08LC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one unit, so the air is cleaned, regulated and lubricated in a single mounting. This GC200C08LC2 is the 200 size with a PT1/4 (1/4 in) PT-threaded port. The filter section carries the standard 40 um element with a differential-pressure drain, the regulator is the low-pressure type (L) fitted with an external round gauge scaled in psi (code C2), and no reverse/check valve is fitted. The mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing); the medium is compressed air only.
This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and with choices of drain type, filter grade (40 um standard, 5 um with code W), gauge style and scale, thread (PT standard, G and NPT as order options) and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the flow and datasheet figures for your application before ordering.
| Model | GC200C08LC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
On a palletizer or case-erector circuit that runs grippers and clamp cylinders from a low-pressure header, this unit cleans the supply with the 40 um element, holds the reduced setpoint with the low-pressure regulator and meters oil mist to the cylinders, all from one PT1/4 connection.
Spinning and winding machinery uses many small air cylinders and thread-tension actuators that need lubricated, low-pressure air. Mounted at the machine inlet, this combination conditions the whole frame supply and the psi-scaled round gauge lets operators check the setpoint at a glance.
Sorting and conveyor lines with diverter gates and stopper cylinders run continuously and benefit from lubricated air. This three-unit set at the line drop filters water and particulate, regulates the low circuit pressure and feeds oil mist downstream to extend actuator life.
Start with the size and port: the 200 size with a 1/4 in PT port suits compact supply lines, and stepping up to 300, 400 or 600 gives larger ports and more flow capacity - match the step to the air demand of the circuit rather than the fitting alone. Because this is the low-pressure type (L), it is intended for circuits regulated well below standard pressures; the exact adjustment range for the low-pressure type is not published in the sheet we quote from, so confirm the range against your setpoint with us before ordering. The drain here is the differential-pressure type (default); automatic (A) and manual (M) drains are available if you prefer hands-off or scheduled draining. The 40 um element is the standard grade; specify W for the 5 um grade where finer particulate removal matters. This unit comes with the external round gauge scaled in psi; square embedded gauges and MPa or bar scales are the other catalogue choices. Thread is PT as standard - order G (BSPP) or NPT if your piping needs it - and the bracket is included.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your line pressure, set pressure and the air consumption of the equipment downstream, and we will confirm the flow and sizing from the datasheet for this exact model before you order.
L marks the low-pressure regulator type, intended for circuits regulated below standard pressures; its exact adjustment range is not published in the sheet we quote, so confirm it with us against your setpoint. C2 means the external round gauge is fitted and scaled in psi - square embedded gauges and MPa or bar scales are the other catalogue options. The drain on this unit is the differential-pressure type; automatic (A) and manual (M) drains can be ordered instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.