The AirTAC GC200C08LC2GK AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC200C08LC2GK is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC200 unit for a G1/4 (1/4 in) port. The filter element is the standard 40 um grade and removes water and particulate before the air reaches the regulator, and the differential-pressure drain bleeds collected condensate as the pressure differential across the element builds. The regulator is the low-pressure type, so it is intended for circuits that hold a lower downstream setting than a standard unit, and the exact adjustment range for this low-pressure configuration is not published, so we confirm it against the datasheet on request. A round external gauge on a psi scale is fitted, a reverse/check valve is included to hold the downstream setting, and a mounting bracket is supplied. The filter bowl is metal.
This is a genuine AirTAC part. The GC combination is available in sizes 200, 300, 400 and 600 with a matching port step, and each size can be ordered with a different filter grade (5 um, code W), drain type, gauge scale (MPa, psi or bar), thread (PT standard, with G and NPT as order options) and valve choices. Flow is published as curves rather than a single rated figure, so send us your application details and we will confirm the sizing and datasheet figures before you order.
| Model | GC200C08LC2GK AirTAC F.R.L. Combination, G1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feed the filter-regulator-lubricator set ahead of the cylinder and valve bank on a cartoning or case-packing line: water and swarf are stripped at 40 um, the low-pressure regulator holds a gentle downstream setting for light-duty actuators, and the lubricator mists oil to keep cylinder seals working.
On a laboratory or QA test rig that runs pilot valves and small fixtures at reduced pressure, the low-pressure regulator suits the lower setting, the round psi gauge gives a direct reading for the test record, and the check valve holds the setting if supply pressure dips mid-test.
Mount the combination at the drop feeding pusher and gate cylinders on a bottling conveyor: clean, regulated, lubricated air extends cylinder service life in a wet environment, and the differential-pressure drain clears condensate without a manual walk-round.
Start with the port and size: this unit is the 200 size on a G1/4 port, the smallest step in the range, so check the flow your circuit needs at the working pressure before fixing on 200 versus stepping up to 300, 400 or 600. Because flow is published as curves and not a single rated number, ask us to confirm the sizing against your application rather than estimating. The regulator here is the low-pressure type; if your circuit needs a higher setting range, the standard type is the alternative to discuss. The 40 um element is the standard grade; specify the W code if the application needs 5 um filtration. Drain is differential-pressure as standard, with automatic and manual drain available if the installation suits them better. The fitted gauge reads in psi; MPa and bar scales can be ordered instead, and the embedded square gauge is the standard option with the external round gauge as the alternative. Thread is G on this code, with PT as the standard and NPT available to order, and a mounting bracket is included.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Send us your application details and we will confirm the flow curve and sizing from the datasheet before you order.
The L in the code marks the low-pressure regulator variant, intended for circuits that hold a lower downstream setting than the standard type. The exact adjustment range for this low-pressure configuration is not published in the material we hold, so we confirm it on request; the standard-type GC units are the alternative if you need the usual range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.