verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um

The AirTAC GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.94 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled in one train so the air is cleaned, regulated and then lubricated before it reaches your cylinders, valves and air tools. This configuration is the 200 size with a PT1/4 (1/4 in) port. The filter element is the fine 5 um grade (code W) and the bowl drains by differential pressure, so condensate is expelled automatically whenever the pressure differential across the element is high enough - no daily manual draining needed. The regulator is the low-pressure type, and a round gauge scaled in psi is fitted so the set pressure can be read and adjusted directly. A mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, with a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, gauge type and scale, PT, G or NPT threads, and standard or low-pressure regulation. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Published flow data appears as curves rather than a single rating, so ask us and we will confirm the flow and datasheet figures for your application on request.

GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um Technical Specifications

ModelGC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um Is Used

precision_manufacturing

Pick-and-place robot cells

Feeding the gripper and actuator circuits of a pneumatic pick-and-place cell: the 5 um element protects the directional valves from particulate and water, the low-pressure regulator holds a gentle gripping pressure, and the lubricator mists oil to the cylinder seals through a 1/4 in PT supply.

factory

Carton-sealing and packaging machines

Supplying the seal cylinders and flap-folders on a packaging line, where the differential-pressure drain keeps condensate out of the valves without an operator stopping the machine, the psi gauge lets the line technician set and verify box-clamp pressure at a glance, and the lubricator keeps the cylinders running smoothly shift after shift.

conveyor_belt

Bottling-line conveyor stops and pushers

Air prep for the stopper, pusher and lift cylinders along a bottling conveyor: the fine 5 um filtration keeps the small control valves from sticking, the regulator holds a stable low pressure for gentle product handling, and the oil mist extends the life of the high-cycle cylinders.

Is the GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um the Right Station?

Start with the size and port: 200 through 600 step up in both port size and flow capacity, so match the size to the air consumption of the downstream circuit - the 200 size with its 1/4 in PT port suits compact machines and individual cells. Next choose the drain: differential-pressure (as fitted here) drains itself on pressure differential, automatic drains on a timer-free float principle, and manual means someone opens the drain valve. Choose the filter grade: 40 um is the standard element for general plant air, while the 5 um (W) element fitted here is the finer choice where valves and instruments need cleaner air. Then pick the gauge: embedded square or external round, scaled in MPa, psi or bar - this unit carries a round psi gauge. Thread is PT as standard with G (BSPP) and NPT available to order, and a bracket is included. Note this is the low-pressure regulator type; the exact adjustment range for the low-pressure version is not published in the sheet we work from, so ask us to confirm it. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a flow figure for this unit. Tell us your port size, working pressure and the air consumption of the downstream equipment, and we will confirm the flow from the datasheet curves on request before you order.

The W in the code GC200C08LC2W selects the fine 5 um filter element instead of the standard 40 um element, which suits circuits with sensitive valves or instruments; the 40 um element remains available if you prefer it. The L selects the low-pressure regulator type, intended where the circuit needs lower set pressures than the standard version; the exact adjustment range for the low-pressure type is not published in our sheet, so ask us to confirm it for your application.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08LC2W AirTAC F.R.L. Combination, PT1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08LC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.