The AirTAC GC200C08LF2 AirTAC F.R.L. Combination Unit PT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C08LF2 is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. This size 200 unit is threaded PT1/4 (1/4 in) and is built as the low-pressure regulator type, for circuits that must run below standard line pressure. The filter element is the standard 40 um grade, the filter and lubricator bowls are polycarbonate (PC), and the filter bowl uses differential-pressure draining. A square pressure gauge scaled in psi is fitted, and the set includes a mounting bracket.
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and with choices of drain type, 5 um (W) or 40 um filtration, gauge scale, thread (PT standard; G and NPT as order options) and reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GC200C08LF2 AirTAC F.R.L. Combination Unit PT1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds a pneumatic clamping or holding circuit on a machining fixture where the workpiece needs a reduced, stable supply pressure rather than full line pressure; the 40 um filter keeps scale and pipe debris out of the valve stack while the lubricator mists the clamp cylinders.
A point-of-use set for a packaging machine's pick-and-place and sealing cylinders: water and particulate are removed upstream, pressure is trimmed to the machine's setting, and oil mist conditions the cylinders and valves.
Serves the air cylinders that divert, stop and push product along a conveyor line, delivering clean, regulated and lubricated air at one take-off point instead of three separate components.
The real choices in this family are decodable from the code. Step through sizes 200/300/400/600 and ports 1/8 to 1 in to match the pipe and the flow your line needs. Choose the drain type where it applies: differential-pressure (default), automatic (A) or manual (M). Filter grade is 40 um standard or 5 um with code W. Gauges are an embedded square gauge (external round optional) with MPa, psi or bar scales, and thread is PT as standard with G (BSPP) and NPT as order options. Brackets are included on this unit. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number we can quote here. Tell us your line pressure and the flow your actuators need, and we will confirm sizing from the datasheet on request.
This GC200C08LF2 is built as the low-pressure regulator variant rather than the standard type, intended for circuits held below normal line pressure. The exact adjustment band for the low-pressure build is not published in the summary data, so we confirm it from the datasheet on request. For comparison, standard-type GC units carry a published 0.15-0.9 MPa (20-130 psi) band with differential-pressure or automatic drain, and 0.05-0.9 MPa (7-130 psi) with manual drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.