The AirTAC GC200C08LF2W AirTAC F.R.L. Combination, PT1/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C08LF2W is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply set. This 200-size unit is threaded PT1/4 (1/4 in), carries a 5 um filter element (the W grade, against the 40 um standard), drains its filter bowl by differential pressure, and is fitted with an embedded square gauge reading in psi. The regulator is the low-pressure type, the filter and lubricator bowls are polycarbonate (PC) on this 200 size, a mounting bracket is included, and no reverse (check) valve is fitted.
This is a genuine AirTAC part. The GC range spans sizes 200 to 600 with ports from 1/8 in to 1 in, and options include automatic or manual drains, a 40 um or 5 um element, gauge scales in MPa, psi or bar, and G (BSPP) or NPT threads in place of the PT standard. Flow for this combination is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GC200C08LF2W AirTAC F.R.L. Combination, PT1/4, 5 um |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Supplies filtered, regulated and lubricated air to a spot-welding robot's gripper and valve manifold, with the low-pressure regulator set below full line pressure.
Feeds the air cylinders and ejectors on a carton case-packing conveyor, with the lubricator maintaining a light oil mist to downstream actuators.
A combined FRL set at each machine drop in a bottling hall, so filtration, regulation and lubrication are installed and serviced at one station.
Size steps up through the 200/300/400/600 series with larger ports and more flow, so pick the size whose flow curve covers your demand at your working pressure - we can check this against the datasheet on request. On this unit the choices are already set: a 5 um element (W) instead of the 40 um standard, a differential-pressure drain, a square gauge scaled in psi, and a low-pressure regulator. If you would rather have the standard 40 um grade, an automatic or manual drain, or a different gauge scale, those are available in neighbouring codes. Thread is PT as standard; G (BSPP) and NPT are order options, and a mounting bracket is included. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not a single rated figure, so we do not quote a number here. Send us your working pressure and air demand and we will confirm the flow from the datasheet on request.
The trailing W in the code selects the 5 um filter grade; the catalogue standard is 40 um. Choose 5 um where downstream equipment needs finer particulate removal. Both grades fit the same GC200 filter body, and the differential-pressure drain works with either.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.