verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08MC2WG AirTAC F.R.L. Combination, G1/4

The AirTAC GC200C08MC2WG AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.42 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08MC2WG AirTAC F.R.L. Combination, G1/4

The GC200C08MC2WG is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. This configuration is built for 1/4 in lines with G (BSPP) ports, carries the fine 5 um filter element (code W), and uses a manual drain on the filter bowl, so condensate is removed by opening the drain when needed. The standard regulator is fitted with an external round gauge scaled in psi, and the setting range is 0.05-0.9 MPa (7-130 psi). A mounting bracket is included.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with a choice of PT, G or NPT thread, drain type, filter grade and gauge scale, with a maximum inlet pressure of 1.0 MPa (145 psi). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC200C08MC2WG AirTAC F.R.L. Combination, G1/4 Technical Specifications

ModelGC200C08MC2WG AirTAC F.R.L. Combination, G1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08MC2WG AirTAC F.R.L. Combination, G1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08MC2WG AirTAC F.R.L. Combination, G1/4 Is Used

build

Body-shop spray-gun air supply

Feeds paint spray guns on a 1/4 in drop line: the 5 um element keeps water and particulate out of the finish, the regulator holds a steady gun pressure read on the psi gauge, and the lubricator is skipped at the gun side or used upstream for air tools on the same bench.

conveyor_belt

Carton-sealing packaging line

Supplies the cylinders and air cylinders on a case-sealing conveyor station: filtered, regulated and lubricated air in one drop, with the manual drain emptied at shift checks and the psi gauge giving operators a visible setpoint.

precision_manufacturing

CNC pneumatic clamping circuit

Conditions the air feeding a machine-tool clamping or fixture-actuation circuit: clean, dry-enough air at a fixed regulated pressure with oil mist for the actuator seals, mounted on the bracket beside the machine's air inlet.

Is the GC200C08MC2WG AirTAC F.R.L. Combination, G1/4 the Right Station?

Start with the port step: this unit is the size 200 body on 1/4 in ports, so step up to GC300/400/600 if the line needs more flow capacity - we can check the published flow curves against your demand on request. The drain here is manual, which suits points where someone is already at the machine; choose the automatic or differential-pressure drain variant for unattended duty. The 5 um element (code W) is the finer option over the 40 um standard, and the fitted round gauge reads in psi; MPa and bar scales are also available. Thread is G (BSPP) on this code, with PT and NPT orderable, and the bracket is included.

Before ordering, send us your application details: because flow is published as curves and not a single rating, we will confirm sizing against your air demand rather than guess.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08MC2WG AirTAC F.R.L. Combination, G1/4 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and air demand and we will confirm the flow from the datasheet curves for this 1/4 in, size 200 unit before you order.

This code carries the manual drain (M): condensate collected in the filter bowl is released by opening the drain, which suits stations checked as part of a routine. If the unit will sit unattended, the GC series is also offered with automatic (A) or differential-pressure (default) draining - ask us for those variants.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08MC2WG AirTAC F.R.L. Combination, G1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MC2WG and will confirm price, stock and lead time — usually within 7-8 hours.