verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08MF2WG AirTAC F.R.L. Combination, G1/4

The AirTAC GC200C08MF2WG AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.43 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08MF2WG AirTAC F.R.L. Combination, G1/4

The GC200C08MF2WG is a three-piece AirTAC GC-series F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-treatment set. This size 200 unit carries a G1/4 (BSPP) port, a 5 um filter element for finer water and particulate removal than the standard 40 um grade, and a manual drain on the filter bowl that you open by hand to expel collected condensate. The regulator is the standard type with an embedded square gauge reading in psi, and no reverse/check valve is fitted. A mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauge scales and thread options, so a matching unit can be specified for the rest of the range. Flow figures for this series are published as curves rather than a single rating - ask us and we will confirm the datasheet figures for your application on request.

GC200C08MF2WG AirTAC F.R.L. Combination, G1/4 Technical Specifications

ModelGC200C08MF2WG AirTAC F.R.L. Combination, G1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08MF2WG AirTAC F.R.L. Combination, G1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08MF2WG AirTAC F.R.L. Combination, G1/4 Is Used

factory

General plant air drop preparation

Fitted at the point where a compressed-air drop feeds a production cell: the filter removes water and particles, the regulator holds a steady working pressure, and the lubricator carries a fine oil mist to the tools and cylinders on that line.

conveyor_belt

Conveyor and packaging line air supply

Mounted ahead of the valve bank on a conveyor or packaging machine, this combination conditions the supply in one assembly - clean, regulated, lubricated air for the diverters, pushers and gripper cylinders that move product along the line.

precision_manufacturing

Machine-tool pneumatic clamping circuits

Installed on the air feed to clamping and workholding fixtures on a machining centre, where the 5 um element protects fine components from particulate and the regulator holds the clamping pressure steady while the lubricator conditions the actuator air.

Is the GC200C08MF2WG AirTAC F.R.L. Combination, G1/4 the Right Station?

Start with the size and port: the GC series steps through sizes 200, 300, 400 and 600, each with larger ports and higher flow capacity, so match the port (here G1/4) and the size step to the air demand of the circuit. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering. Then choose the drain: manual (this unit, opened by hand), automatic, or the differential-pressure default - manual suits points where someone is already present at the machine, while automatic removes the routine. Choose the filter grade: 40 um standard or 5 um (code W, as fitted here) for finer protection downstream. The gauge is an embedded square type with MPa, psi or bar scales (this unit reads psi); an external round gauge is optional. Thread is G (BSPP) on this unit, with PT as the standard and NPT orderable as a specification option. A mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08MF2WG AirTAC F.R.L. Combination, G1/4 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so there is no one figure we can quote honestly. Tell us your working pressure and air demand and we will confirm the datasheet flow figures for this unit on request before you order.

The M in the code selects a manual drain: you open the filter bowl by hand to release collected condensate, instead of the differential-pressure drain (the default) or an automatic drain. The W in the code selects the 5 um filter element instead of the standard 40 um grade, giving finer filtration of water and particulate on the same bowl.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08MF2WG AirTAC F.R.L. Combination, G1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.