The AirTAC GC200C08MLF2K AirTAC F.R.L. Combination, PT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one air-treatment station. This GC200C08MLF2K is the size 200 unit with a 1/4 inch PT port. The filter section carries a 40 um element with a metal bowl drained by the manual drain fitted, the regulator section is the low-pressure type with an embedded square gauge scaled in psi, and a reverse/check valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. A mounting bracket is included.
This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and is configurable by drain type, filter grade (40 um standard, 5 um optional), gauge scale (MPa, psi or bar), thread (PT standard, G or NPT to order) and reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GC200C08MLF2K AirTAC F.R.L. Combination, PT1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to the cylinders and actuators on a cartoning or wrapping line, with the low-pressure regulator set to the machine's supply band and the psi gauge giving operators a local reading.
Conditions the air feeding diverters, stoppers and lifters along a conveyor system, where the 40 um element protects valves from water and particulate and the lubricator mists oil to the downstream cylinders.
Supplies treated air to pneumatic clamps and swing cylinders at a bench or robotic assembly cell, with the check valve holding the set condition and the manual drain suiting a station serviced each shift.
Start with the size and port: the 200 series steps up through 300, 400 and 600, with larger sizes carrying larger ports and more flow, so match the 1/4 in PT port here against your supply line and the flow curve for the size. Choose the drain to suit access: this unit has a manual drain, which suits attended installations; automatic and differential-pressure drains are available if the bowl cannot be drained by hand. The 40 um element is the standard grade; specify the W option for 5 um where finer particulate removal is needed. The square gauge on this unit reads in psi; MPa and bar scales are alternatives. Thread is PT as standard, with G (BSPP) and NPT as orderable options.
Note that this is the low-pressure regulator type, so confirm the operating band suits your line. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Ask us and we will confirm the flow curves and datasheet figures for this size 200, 1/4 in PT unit against your application before you order.
The M in the code specifies a manual drain on the filter bowl, which suits installations where the bowl can be drained as part of routine checks; automatic and differential-pressure drains are the alternatives. The F2 specifies the embedded square gauge scaled in psi, with MPa and bar scales available as options.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.