AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um

The AirTAC GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$121.11 $128.61Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um

The GC30010AF2WT is a three-piece AirTAC GC-series F.R.L. combination: a filter, a pressure regulator and a lubricator assembled as one air-preparation set. This configuration is sized 300 with a NPT3/8 (3/8 in) port, carries the fine 5 um filter element (code W), drains condensate automatically, and is fitted with the embedded square gauge scaled in psi. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), so a single set-up filters water and particulate from the compressed air, holds a stable downstream pressure, and feeds oil mist to downstream tools and actuators. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, three thread types (NPT on this code), a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.

GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um Technical Specifications

ModelGC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um Is Used

precision_manufacturing

Pneumatic press and clamping fixtures

Feeds a production press line where filtered, moisture-free air at a held setpoint keeps clamping cylinders consistent through the shift, with the lubricator protecting cylinder seals and valve spools.

factory

Packaging machine air supply

Conditions the supply to a carton-forming and sealing line: the 5 um element guards directional valves from particulate, the regulator holds a stable working pressure, and oil mist lubricates the machine's air cylinders.

settings_input_component

Assembly-cell air drops

Serves a bench of air tools and torque drivers at a single conditioned drop, so operators get clean, regulated, lubricated air without per-tool preparation, and the automatic drain keeps the bowl clear unattended.

Is the GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um the Right Station?

Size your GC set by the port and flow step: 200, 300, 400 and 600 correspond to increasing port sizes and flow capacity, with this unit at size 300 and NPT3/8. Choose the drain to match maintenance access: automatic drain (as fitted here) removes condensate without operator attention, manual drain suits attended installations, and the differential-pressure drain is the default. Pick 40 um for general protection or 5 um (code W, as here) where finer particulate removal matters, such as before precision valves or instruments. Select the gauge scale (MPa, psi or bar) and thread finish (NPT on this code); a mounting bracket is included. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application and we will confirm the flow data from the datasheet on request, and check the size 300 / NPT3/8 step against your demand before you order.

The trailing A in the code sets the automatic drain, so condensate is expelled from the filter bowl without manual attention - useful where the set is mounted in a less accessible spot. The W sets the 5 um fine filter element instead of the 40 um standard, for applications that need finer particulate removal. Both are decodable choices you can specify differently on other GC models.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30010AF2WT AirTAC F.R.L. Combination, NPT3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010AF2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.