verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8

The AirTAC GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$122.34 $129.84Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8

The AirTAC GC30010MF2TK is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air from a single assembled set: a separate filter, a separate regulator and a separate lubricator. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The bowls on the 300 size are PC (polycarbonate), so the unit suits standard compressed-air service where the bowls are protected from impact and chemicals.

This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in and thread choices of three thread types (NPT on this code). Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8 Technical Specifications

ModelGC30010MF2TK AirTAC F.R.L. Combination, NPT3/8
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8 Is Used

factory

Assembly-line pneumatic tool supply

Feeds filtered, regulated and lubricated air to impact drivers, nut runners and air ratchets at assembly benches, so tools receive clean, moisture-reduced air at a stable set pressure with oil mist for internal lubrication.

conveyor_belt

Packaging and cartoning machine air prep

Conditions the air feeding cylinders and grippers on a packaging line, where the manual-drain filter bowl is emptied during scheduled changeovers and the check valve holds the set pressure against upstream dips.

engineering

Maintenance-shop air drop conditioning

Installed at a workshop air drop to serve air hammers, blow guns and small presses, giving technicians one point where water and chips are strained out, working pressure is set on the psi gauge, and tool oil misting is controlled.

Is the GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8 the Right Station?

Start with the port and size step: this unit is 300 size with a 3/8 in NPT port; smaller and larger steps (200/400/600, 1/8 in to 1 in) exist, so match the step to the air demand of the line. Drain choice matters: this configuration has a manual drain, where an operator opens the drain periodically; automatic (code A) and differential-pressure (blank) drains are available if you cannot rely on manual attention. Filter grade is 40 um standard here; specify code W for the 5 um element if downstream equipment needs finer filtration. The square gauge is fitted and reads in psi (scale 2); MPa and bar scales and an external round gauge are options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8 FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your line pressure, set pressure and air demand, and we will confirm the flow figures from the datasheet and check the sizing against your application before you order.

Code M in GC30010MF2TK means the filter bowl has a manual drain: an operator opens it periodically to discharge collected water. If the unit sits where nobody can drain it regularly, choose the automatic drain (code A) or the differential-pressure drain (blank) version instead; the regulation range of 0.05-0.9 MPa (7-130 psi) applies to this manual-drain configuration.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30010MF2TK AirTAC F.R.L. Combination, NPT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30010MF2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.