The AirTAC GC30015ALF2TK AirTAC F.R.L. Unit, NPT1/2, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC30015ALF2TK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one set, so compressed air is cleaned of water and particulate, held at a set working pressure, and carrying a fine oil mist to downstream equipment. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The filter section carries the standard 40 um element with an automatic drain that expels collected condensate without manual attention, the regulator is the low-pressure type with a fitted square gauge scaled in psi, and a reverse/check valve is fitted to hold the downstream circuit against backflow.
This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with matching port steps, and options include manual or differential-pressure drains, a 5 um filter element (code W), gauge scale choices and G or NPT threads. Flow figures for this series are published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GC30015ALF2TK AirTAC F.R.L. Unit, NPT1/2, Low-Pressure |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-15 |
| Build order | Filter → regulator → lubricator |
Feeding cleaned, regulated and lubricated air to the cylinder and valve manifold bank of a production assembly cell, with the automatic drain handling condensate during multi-shift running.
Supplying the air cylinders and grippers on a carton-forming and sealing conveyor line, where the low-pressure regulator holds a stable working pressure and the lubricator keeps actuation smooth.
Conditioning the air feed to a CNC machine tool's clamping and tool-change circuits, with the 40 um filter protecting valves and the check valve holding the clamp circuit against supply backflow.
Start with the port step: size 300 gives a NPT1/2 connection, and moving up or down a size changes both the port and the flow capacity, so match the size to the air demand of the machine rather than only the pipe thread. The drain choice matters in practice: automatic drain (this model) suits unattended or hard-to-reach installations, manual drain suits regularly serviced stations, and the differential-pressure type is the default. The standard element is 40 um; specify code W for the 5 um grade where finer filtration is needed. Gauge scale is selectable (MPa, psi or bar) and this unit ships with the square gauge in psi. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow for this series is published as curves, not a single rated figure, so please ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment and we will confirm the correct size from the datasheet on request.
The A in the code specifies the automatic drain on the filter bowl: collected condensate is expelled without operator attention, which suits unattended installations. The GC family is also available with a manual drain or the differential-pressure (default) drain - just order the corresponding code.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.