The AirTAC GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain

The GC30015MC2T is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one package. This configuration is sized 300 with a NPT1/2 port, carries the standard 40 um filter element for water and particulate removal, uses a manual drain on the filter bowl (polycarbonate at this size), and has a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi) with a round psi gauge fitted. The lubricator feeds oil mist downstream to keep air tools and cylinders running smoothly.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with a choice of ports and threads, filter grade 40 um standard or 5 um (code W), manual, automatic or differential-pressure drains, gauge type and scale, and a reverse/check valve option. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request. This version has NPT ports (the T in the order code) for North American pipe fittings.

GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain Technical Specifications

ModelGC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain Is Used

precision_manufacturing

CNC machining cell air supply

Feeds filtered, regulated and lubricated air to the machine tool's clamping fixtures, tool changers and pneumatic actuators, with the psi gauge giving operators a visible setpoint at the machine.

factory

Automotive paint shop air preparation

Prepares the air line serving spray guns and air-assisted equipment in a body shop: water and particulate removed at 40 um, pressure held steady by the regulator, and oil mist delivered downstream.

conveyor_belt

Packaging and case-sealing line

Supplies the carton sealers, diverters and pick-and-place cylinders on a packaging conveyor line, keeping moisture and debris out of the valves while the lubricator protects the cylinders.

Is the GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain the Right Station?

Start with the port step: this unit is size 300 with a NPT1/2 port; step up to size 400 or 600 if your line needs more flow capacity, or down to 200 for compact circuits. Choose the drain to match how the unit is attended: this code has a manual drain (drained by hand), while automatic and differential-pressure drains are available for unattended installations. Filter grade is the standard 40 um here; specify 5 um (code W) where finer particulate removal matters. The gauge on this code is a round gauge with a psi scale; embedded square gauges and MPa or bar scales are the other catalogue options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow figure. Send us your application details and we will confirm the flow and sizing figures from the datasheet on request.

The M in GC30015MC2T specifies a manual drain, meaning the filter bowl is drained by hand as part of routine maintenance. If the unit will be installed where nobody drains it regularly, the same size is available with an automatic or differential-pressure drain - just ask for the alternative code.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30015MC2T AirTAC F.R.L. Combination, NPT1/2, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30015MC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.