The AirTAC GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain

The GC30015MLF2T is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply package. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. In use it filters water and particulate from the compressed air, holds the downstream pressure the circuit needs, and adds a controlled oil mist for pneumatic tools and cylinders.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, with a choice of drain type, 40 um or 5 um filtration, gauge scale, thread form (NPT on this code) and bracket options. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the sizing figures from the datasheet for your application.

GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain Technical Specifications

ModelGC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain Is Used

factory

Automotive paint booth air supply

Feeds filtered, regulated and lubricated air to spray guns and air-assisted equipment in a paint booth line, where water and particle carry-over would spoil finish quality and the low-pressure regulator type suits circuits run below standard mains pressure.

conveyor_belt

Carton-sealing machine on a packaging line

Supplies the pneumatic cylinders and flap-folders on a carton sealer with clean air, a steady set pressure and oil mist, keeping the sealing head cycling consistently through a shift.

precision_manufacturing

CNC machining cell clamping circuit

Conditions the air feeding pneumatic workholding clamps and tool-change actuators on a CNC cell, protecting the valves from water and grit while holding the clamp pressure the setup calls for.

Is the GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain the Right Station?

Start with the port step: this unit is size 300 with 1/2 inch NPT ports, one of five sizes (200/300/400/600) that step up in both port size and flow capacity, so match the size to the air demand of the circuit rather than only to the pipe thread. Next choose the drain: this code has a manual drain, where the bowl is emptied by hand at intervals; automatic and differential-pressure drains are available on the same size if you prefer draining without operator attention. Filtration is the standard 40 um grade here, with a 5 um element (code W) available where finer particle capture is needed. The gauge on this unit is the embedded square type with a psi scale; MPa and bar scales and an external round gauge are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves and not a single rated figure, send us your application details and we will confirm the correct size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so there is no honest one-line flow figure we can quote. Tell us your application and air demand and we will confirm the sizing from the datasheet on request before you order.

The M in GC30015MLF2T means the filter bowl drains manually: someone opens the drain at service intervals and empties collected water. It suits stations that are checked regularly. If the unit will sit unattended, the same size is available with an automatic or differential-pressure drain so condensate is removed without operator attention.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30015MLF2T AirTAC F.R.L. Combination NPT1/2 Manual Drain