verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C08AC2GK AirTAC F.R.L. Combination, G1/4

The AirTAC GC300C08AC2GK AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$121.28 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C08AC2GK AirTAC F.R.L. Combination, G1/4

The GC300C08AC2GK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator set up as one treatment train. This configuration is built for a G1/4 (1/4 in) port with G thread, carries a 40 um filter element, and uses an automatic drain on the filter bowl so collected water is expelled without manual attention. The standard regulator adjusts across 0.15-0.9 MPa (20-130 psi) and a round gauge on a psi scale is fitted so downstream pressure can be read and set directly. A reverse/check valve is included, and the set comes with a mounting bracket for panel or wall fixing. Maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port sizes, and each element can be specified with drain type, filter grade (40 um standard, 5 um optional), gauge style and scale, thread (PT standard; G and NPT as order options) and bracket choices. Flow is published by AirTAC as curves rather than a single rated figure, so we confirm the datasheet and sizing figures for your application on request.

GC300C08AC2GK AirTAC F.R.L. Combination, G1/4 Technical Specifications

ModelGC300C08AC2GK AirTAC F.R.L. Combination, G1/4
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C08AC2GK AirTAC F.R.L. Combination, G1/4

GC300G-series F.R.L. combination, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C0
Build orderFilter → regulator → lubricator

Where the GC300C08AC2GK AirTAC F.R.L. Combination, G1/4 Is Used

factory

Automotive paint-shop air drops

Feeds spray guns and air-assisted applicators on a paint line, where the filter removes water and particulate, the regulator holds a steady set pressure, and the lubricator mists oil to keep gun spindles and air motors running smoothly.

conveyor_belt

Carton-sealing conveyor cylinders

Supplies the pneumatic cylinders and air clamps on a packaging conveyor, giving the machine one point where clean air, a fixed working pressure and cylinder lubrication are all set and visible on the psi gauge.

precision_manufacturing

CNC machine pneumatic clamping

Conditions the air feeding a machining centre's clamping fixtures and tool-change actuators: the 40 um filter and automatic drain protect the valves, the regulator locks clamp pressure, and the lubricator conditions the actuator seals.

Is the GC300C08AC2GK AirTAC F.R.L. Combination, G1/4 the Right Station?

Start with the size and port step: GC300 with a 1/4 in port suits compact supply drops; step up to GC400 or GC600 when the line demands larger ports and more flow, or down to GC200 for small circuits. Choose the drain on the filter bowl: automatic (as here) empties condensate unattended, manual needs an operator, and differential-pressure draining suits lines where a pressure signal is preferred. Filter grade is 40 um as standard; specify the W code for 5 um where finer particulate removal matters. Pick the gauge style and scale (square embedded or external round; MPa, psi or bar) to match how your technicians set pressure. Thread is PT as standard, with G (BSPP) and NPT available as order options, and the bracket can be kept or omitted. Because AirTAC publishes flow as curves rather than a single rating, ask us to confirm the sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.

GC300C08AC2GK AirTAC F.R.L. Combination, G1/4 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one l/min, m3/h or SCFM number we can state. Tell us your line pressure and the air demand of your equipment and we will confirm the sizing from the datasheet on request.

The A in the code GC300C08AC2GK means the filter bowl drains itself automatically, so condensate is expelled without an operator opening a valve - useful on lines that run unattended. The GC family also offers manual and differential-pressure drain versions if you prefer a different arrangement.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C08AC2GK AirTAC F.R.L. Combination, G1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C08AC2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.