verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um

The AirTAC GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.45 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um

The GC300C08AF2W is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. This size 300 configuration is threaded PT1/4 (1/4 in), carries a 5 um filter element for finer water and particulate removal, and drains its filter bowl automatically, so condensate is ejected without daily attention. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and an embedded square gauge with a psi scale is fitted so the set pressure can be read at a glance. The set is rated for a maximum inlet pressure of 1.0 MPa (145 psi) and operates from -5 to 70 C in non-freezing conditions; at this size the bowls are polycarbonate.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, thread options PT (standard), G and NPT, automatic or manual bowl drainage, 40 um or 5 um filtration, gauge scales in MPa, psi or bar, and an included mounting bracket. Rated flow for this combination is published as curves rather than a single figure, so ask us to confirm the datasheet numbers for your application before you order.

GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um Technical Specifications

ModelGC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C0
Build orderFilter → regulator → lubricator

Where the GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um Is Used

factory

Paint and finishing lines

Feeds spray guns and atomising stations on a finishing line with water and particulate removed at 5 um, pressure held steady at the gun, and a light oil mist to keep air motors and triggers running smoothly.

precision_manufacturing

CNC machine shops

Supplies the pneumatic clamps, tool-changer actuators and air-blast nozzles on a machining centre, where regulated pressure protects clamping force and clean, lubricated air extends cylinder seal life.

conveyor_belt

Packaging and bottling lines

Prepares the air feeding grippers, diverters and case-erector cylinders along a packaging conveyor, with automatic drainage handling condensate during continuous shifts and the psi gauge letting line staff verify set pressure at a glance.

Is the GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um the Right Station?

Choose the size by the port and flow step: size 300 with its PT1/4 port suits lines plumbed with 1/4 in air piping, while stepping up to size 400 or 600 gives a larger port and more flow capacity. Drainage here is automatic, the right choice when the unit is mounted where daily manual draining is impractical; a manual-drain variant suits very dry installations or easily reached bowls. The 5 um element (code W) is fitted instead of the standard 40 um element - keep it where downstream valves, cylinders or instruments tolerate less particulate, and note that a finer element loads with contamination faster. The fitted square gauge reads in psi; MPa or bar scales and an external round gauge are available as alternatives. Thread is PT as standard, with G and NPT offered as order options, and the mounting bracket is included. Because flow is published as curves rather than a single rating, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.

GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Send us your required flow and working pressure and we will confirm the figures from the datasheet for this exact PT1/4, size 300 configuration before you order.

The W in the model code specifies the 5 um element in place of the standard 40 um element. It removes finer particulate, which suits downstream valves, cylinders and instruments that tolerate less contamination; the trade-off is that a finer element holds dirt sooner, so the automatic drain and periodic element checks matter more. If your line only needs coarse water and dirt removal, the 40 um standard grade is the lower-maintenance choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C08AF2W AirTAC F.R.L. Combination, PT1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C08AF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.