The AirTAC GC300C08MF2WG AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC300C08MF2WG is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This configuration is built for a G1/4 (1/4 in) port on the GC300 size, with a 5 um filter element (the finer of the two catalogue grades), a manual drain on the filter bowl, an embedded square pressure gauge reading in psi, and a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi). The filter bowl on this 300 size is polycarbonate, and the set carries a maximum inlet pressure of 1.0 MPa (145 psi) with an operating temperature of -5 to 70 C (non-freezing). No reverse/check valve is fitted.
This is a genuine AirTAC part. The GC line is offered in sizes 200, 300, 400 and 600, with port options, drain types, filter grades, gauge scales and thread variants (PT standard; G and NPT to order) across the range. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GC300C08MF2WG AirTAC F.R.L. Combination, G1/4 |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C0 |
| Build order | Filter → regulator → lubricator |
Point-of-use air preparation at assembly-station drop lines: the filter removes water and particles down to 5 um, the regulator holds a steady setting for air tools and fixtures, and the lubricator mists oil to the tools downstream.
Feeding pneumatic cylinders and grippers on a packaging or bottling conveyor: clean, regulated and lubricated air keeps the actuators on the line running consistently through shift after shift.
Supplying pneumatic clamps and tool-change cylinders on a CNC machining cell, where the 5 um element protects the valves and the regulator pins the clamping pressure set on the psi gauge.
Start with the size and port: this unit is the GC300 with a G1/4 (1/4 in) port; if your line needs more or less flow capacity, step up or down through the 200/300/400/600 sizes and their matching ports. This code fixes the real choices for you: 5 um filtration (versus the 40 um standard), a manual drain (versus automatic or differential-pressure), a square gauge on the psi scale, a G thread (PT is the AirTAC standard; G and NPT are order options), and a mounting bracket included.
On sizing: flow for this series is published as curves, not as a single rated number, so we will not quote you a figure here. Send us your application details and we will confirm the correct size and the datasheet flow curve before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.
AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not state a l/min or SCFM number. Send us your application and we will confirm the datasheet flow curve and check the sizing for you on request.
The M in the code specifies a manual drain on the filter bowl: condensate is emptied by hand. Automatic and differential-pressure drain options exist in the GC range, so if you cannot access the unit for regular draining, ask us about those variants before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.