verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8

The AirTAC GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$121.75 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8

The GC300C10ALC2WK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator working as one conditioning stack. This size 300 unit carries a PT3/8 (3/8 in) port, the 5 um filter element (code W) for finer water and particulate removal than the standard 40 um grade, an automatic drain that expels collected condensate without manual attention, and a low-pressure type regulator. A round pressure gauge scaled in psi is fitted, a reverse/check valve is built in, and the mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The filter bowl on this size is polycarbonate.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and can be ordered with manual or differential-pressure draining, the 40 um standard element, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the PT standard. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8 Technical Specifications

ModelGC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8 Is Used

precision_manufacturing

CNC machining cell air supply

Feeding clean, regulated and lubricated air to a CNC cell's pneumatic clamps, tool-change cylinders and chip-door actuators, with the 5 um element guarding fine pilot valves on the machine.

factory

Packaging line actuation

Conditioning the air feeding a packaging line's cylinder-driven carton closers and valve manifolds, where the regulator holds a steady low setpoint and the lubricator mists oil to the cylinders.

conveyor_belt

Conveyor sortation gates

Supplying the air diverters, stoppers and pusher cylinders along a conveyor sortation system, with the automatic drain coping with condensate on a line that runs unattended across shifts.

Is the GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8 the Right Station?

Start with the size and port: 300 with a PT3/8 port suits lines running 3/8 in air drops; step up to 400 or 600, or down to 200, to match your pipe and demand. Choose the filter grade deliberately: the 40 um standard element protects most actuators and valves, while the 5 um element (this unit, code W) is the finer choice for delicate pilot valves and precision tools. Pick the drain to match access: automatic (this unit) where bowls are hard to reach, manual where an operator checks routinely, or differential-pressure as the default. Select the gauge style and scale - embedded square or external round, in MPa, psi or bar - and specify the thread you pipe in: PT is the standard, with G (BSPP) and NPT available as order options. The J code deletes the bracket if you do not want one.

One honest note before you order: AirTAC publishes flow as curves, not a single rated number, and the regulation range for this low-pressure (L) version is not stated in the material we hold. Tell us your line pressure and air demand and we will confirm the sizing and figures against the datasheet before you commit.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8 FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a number. Send us your line pressure and air demand and we will confirm the sizing and the datasheet flow figures for this PT3/8 unit on request.

L marks the low-pressure type of regulator. The standard GC regulation range does not apply to this version, and the exact range for the low-pressure type is not published in the material we hold, so ask us to confirm it against the datasheet before ordering if your setpoint is critical.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C10ALC2WK AirTAC F.R.L. Combination, PT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10ALC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.