verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8

The AirTAC GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.73 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built up as one unit, so incoming compressed air is cleaned of water and particulate, regulated to your set pressure, and given an oil mist for downstream air tools. This GC300C10C2GK is the 300 size with a G3/8 port. It carries the standard 40 um filter element with a differential-pressure drain on the filter bowl, a standard regulator adjustable from 0.15 to 0.9 MPa (20-130 psi), a round psi gauge, and a reverse (check) valve fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options including 5 um filtration (code W), automatic or manual drains, gauge scale in MPa, psi or bar, and G or NPT threads as order options (PT is the standard thread). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.

GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8 Technical Specifications

ModelGC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8 Is Used

factory

Automotive assembly line air tools

Feeding impact wrenches, ratchets and air screwdrivers at assembly stations: the filter removes water and swarf from the shop air, the regulator holds a steady set pressure at the tool, and the lubricator carries an oil mist to keep the tool motors running.

conveyor_belt

Packaging and case-sealing conveyors

Supplying the pneumatic cylinders and stopper gates on a packaging conveyor: clean, regulated air protects the cylinder seals, and the check valve holds the downstream circuit stable when the main supply dips during shift changeovers.

precision_manufacturing

Machine-tool clamping circuits

Air preparation for pneumatic clamps and workholding fixtures on a CNC cell: the 40 um element keeps grit out of the clamping valves, the regulator sets a repeatable clamping pressure, and the lubricated air conditions the actuator side of the circuit.

Is the GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8 the Right Station?

The real choices in this series are the size and port step (200/300/400/600, 1/8 to 1 inch) matched to the flow your line needs; the drain type on the filter bowl (differential-pressure as here, automatic, or manual); the filter grade (40 um standard, 5 um with code W); the gauge and its scale (an embedded square gauge is standard, an external round gauge is optional, in MPa, psi or bar); the thread (PT standard, G or NPT to order); and the reverse/check valve (code K, fitted on this unit). Flow for each size is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8 FAQ

Flow for this series is published as curves in the AirTAC datasheet rather than as a single rated figure, so we do not quote a number here. Send us your required flow and working pressure and we will confirm from the datasheet whether the 300 size at G3/8 is correctly sized for your application before you order.

The filter bowl on this GC300 is fitted with a differential-pressure drain as the standard arrangement: it uses the pressure drop across the filter element to expel collected condensate while the unit is working, so there is no drain code in the model. Automatic (code A) and manual (code M) drains are available as order options if your installation prefers them.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C10C2GK AirTAC F.R.L. Combination Unit, G3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10C2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.