verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8

The AirTAC GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$111.37 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8

The GC300C10MC2WK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one filtered-air supply point. This configuration is size 300 with PT3/8 ports, the 5 um filter element (code W) for finer water and particulate removal, a manual drain on the bowl, a round external gauge reading in psi, a reverse/check valve fitted, and a mounting bracket included. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi) for this manual-drain version, and the maximum inlet pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options include automatic, manual or differential-pressure drains, 40 um or 5 um filtration, gauge style and scale (MPa, psi or bar), a reverse/check valve, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8 Technical Specifications

ModelGC300C10MC2WK AirTAC F.R.L. Combination, PT3/8
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8 Is Used

precision_manufacturing

CNC machining cell air supply

Feeds filtered, regulated and lubricated air to the actuators, chucks and tool-change cylinders on a CNC machining cell, with the 5 um element protecting downstream valve spools and the psi gauge giving operators a local set-point readout.

conveyor_belt

Packaging line cylinder supply

Serves as the drop-in air preparation point for the pick-and-place and clamp cylinders on a packaging conveyor line, where the manual drain suits a station that is already checked each shift and the lubricator keeps cylinder seals running smoothly.

factory

Assembly-station FRL drop

Provides a complete filter-regulator-lubricator drop for pneumatic assembly stations and air tools along a production floor, with the check valve holding the downstream circuit against backflow and the bracket allowing clean panel or frame mounting.

Is the GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8 the Right Station?

Start with the size and port: this unit is size 300 with PT3/8 (3/8 in) ports, one step up from the 1/4 in size-200 units, so step up again to size 400 or 600 if your line needs more flow capacity. Drain choice matters: this version has a manual drain, which means someone drains the bowl on a routine basis; choose automatic or differential-pressure drain codes if the unit will be installed where regular manual attention is impractical. Filtration here is the finer 5 um element (code W); the 40 um standard element suits general supply lines where finer protection is not required. The gauge is the external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue options. The reverse/check valve (code K) is fitted, and the mounting bracket is included. Thread is PT as standard; G (BSPP) and NPT are order options. Because AirTAC publishes flow only as curves and not as a single rated figure, send us your application details and we will confirm the datasheet and sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8 FAQ

AirTAC publishes flow for the GC series as performance curves, not as a single rated figure, so we do not quote a rated flow number. Tell us your application and operating pressure and we will confirm the datasheet and check the sizing against your required flow before you order.

The M in the code GC300C10MC2WK specifies a manual drain on the bowl, so condensate is removed by hand on a routine schedule. The GC series is also available with an automatic drain (code A) or the differential-pressure drain (blank), which suits installations that are not checked daily. This unit also carries the 5 um filter element (code W) instead of the 40 um standard, a round psi gauge, and the reverse/check valve (code K).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C10MC2WK AirTAC F.R.L. Combination, PT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10MC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.