verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2

The AirTAC GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$121.11 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2

The GC300C15AF2WGK is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator built together as one supply unit. This size 300 configuration is threaded G1/2 (G/BSPP), filters to 5 um, drains condensate automatically, regulates with the standard 0.15-0.9 MPa (20-130 psi) spring range, and carries an embedded square gauge scaled in psi. A reverse/check valve is fitted, the mounting bracket is included, and the unit is rated for a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and can be ordered with manual or differential-pressure draining, the 40 um standard filter grade, gauge scaling in MPa, psi or bar, and PT, G or NPT threads. Flow for this size is published as curves rather than a single rating, so ask us to confirm the datasheet figures against your application.

GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2 Technical Specifications

ModelGC300C15AF2WGK AirTAC F.R.L. Combination, G1/2
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2 Is Used

factory

Automotive trim-line air drops

Feeding filtered, regulated and lubricated air to impact wrenches, nutrunners and pneumatic clamps at assembly stations, with the check valve holding the circuit if supply pressure dips.

precision_manufacturing

CNC machining cell supply

Conditioning the air feeding workholding clamps, tool-change actuators and air blast on a machining centre, where the 5 um grade and a stable regulated pressure protect the actuators.

conveyor_belt

Carton sealing on a packaging line

Supplying case erectors and carton sealing heads on a packing conveyor, where the lubricator keeps cylinder seals running and the automatic drain copes with condensate through long shifts.

Is the GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2 the Right Station?

Size is the first decision: 200, 300, 400 and 600 step up in port and flow capacity, so match the size to the air demand of the line rather than to the pipe thread alone. Choose the drain behaviour deliberately: automatic draining (as fitted here) suits unattended duty, manual draining puts the check on the operator, and the differential-pressure default drains on a pressure drop. Filtration is 5 um on this model; 40 um is the standard grade where downstream equipment tolerates coarser air. The gauge can be ordered with MPa, psi or bar scaling, and the thread is available as PT (the standard), G or NPT. Flow is published as curves, not a single rating, so send us your demand figure and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2 FAQ

AirTAC publishes flow for the GC family as curves rather than a single rated figure, so we do not quote a number on the page. Send us your working pressure and required air consumption and we will confirm the sizing from the datasheet on request before you order.

The A in the code specifies the automatic drain, which expels condensate without operator attention. The GC family can also be ordered with a manual drain (code M) or the differential-pressure default; the regulator setting range differs by drain type, so tell us your duty and we will confirm the right variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C15AF2WGK AirTAC F.R.L. Combination, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C15AF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.