verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300C15MF2 AirTAC F.R.L. Combination, PT1/2

The AirTAC GC300C15MF2 AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$100.01 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300C15MF2 AirTAC F.R.L. Combination, PT1/2

The GC300C15MF2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one coordinated set. This configuration is built around a PT1/2 (1/2 in) port with standard PT thread, and the filter section carries a 40 um element with a manual drain on its bowl, so water and particulate are removed by hand-draining the bowl as part of routine maintenance. The standard regulator is fitted with an embedded square gauge reading in psi, giving operators a direct, at-the-panel pressure reference, and the lubricator feeds an oil mist into the downstream air for tools and cylinders that need it.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600, with port options, drain types (manual, automatic or differential-pressure), a 5 um filter element option, gauge scale choices and G or NPT thread variants available to order. Rated flow is published as curves rather than a single figure, so ask us and we will confirm the datasheet and sizing figures for your application on request.

GC300C15MF2 AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC300C15MF2 AirTAC F.R.L. Combination, PT1/2
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300C15MF2 AirTAC F.R.L. Combination, PT1/2

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the GC300C15MF2 AirTAC F.R.L. Combination, PT1/2 Is Used

precision_manufacturing

CNC machining cell air supply

Feeds clean, regulated and lubricated air to a CNC machine's pneumatic clamps, tool-change cylinders and chip-clearing jets, with the psi gauge letting setters verify clamp pressure at the panel and the manual drain cleared during shift-start checks.

factory

Automotive paint shop spray line

Conditions the air feeding paint spray guns and air-assisted applicators: the 40 um filter and manual-drain bowl strip water and debris before the regulator holds a steady set pressure and the lubricator is set to suit the gun manufacturer's air-prep requirements.

conveyor_belt

Packaging and carton-sealing line

Supplies treated air to carton-sealing cylinders, case-erecter actuators and conveyor diverters, where the regulator keeps actuation pressure consistent across the shift and the lubricator maintains the pneumatic cylinders that cycle continuously.

Is the GC300C15MF2 AirTAC F.R.L. Combination, PT1/2 the Right Station?

Start with the size and port: this unit is size 300 with a PT1/2 (1/2 in) PT-threaded port; larger sizes carry larger ports and more flow capacity, so step up or down to match your line. Choose the drain type for the filter bowl - manual (as here) for supervised maintenance, automatic for hands-off condensate removal, or the differential-pressure default - and the filter grade: 40 um standard or 5 um (code W) where finer particulate protection matters. Gauge scale can be specified as MPa, psi or bar, and G (BSPP) or NPT threads are order options if PT does not suit your piping. A mounting bracket is included with this unit.

One honest note before ordering: AirTAC publishes flow for this series as curves, not a single rated number, so we do not quote a flow figure here. Send us your application details and we will confirm the sizing against the datasheet curves on request.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

GC300C15MF2 AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated number, so we do not state a flow figure here. Tell us your application - the actuators or tools involved and your working pressure - and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code means the filter bowl has a manual drain: condensate collected during operation is released by hand as part of routine maintenance, which suits lines with regular operator checks. If you would rather not drain by hand, automatic and differential-pressure drain versions are available in the same series - ask us to quote the variant that fits your maintenance routine.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300C15MF2 AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C15MF2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.