AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8

The AirTAC GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$170.15 $177.65Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8

The GC40010LF2TK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the low-pressure type, fitted with an embedded square gauge reading in psi, and a reverse/check valve is fitted to hold downstream pressure when the supply is lost. Bowls are polycarbonate at this size, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.

This is a genuine AirTAC part. The GC line is available in sizes 200, 300, 400 and 600 with a choice of ports, threads, drains, filter grades, gauge scales and regulator types, so a configuration can be matched to most compressed-air circuits. Because flow is published as curves rather than a single rating, we confirm the datasheet figures for your application on request.

GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8 Technical Specifications

ModelGC40010LF2TK AirTAC F.R.L. Combination, NPT3/8
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8 Is Used

factory

Automotive assembly line air drops

Feeds a row of impact tools and air cylinders at a car-plant assembly station: the filter dries and cleans the drop, the low-pressure regulator sets the working pressure for the tools, and the lubricator mists oil into the tool feed lines.

conveyor_belt

Packaging machine actuation

Supplies the pneumatic cylinders on a carton-forming and sealing machine, where the reverse/check valve holds the set pressure if the shop-air supply drops and the lubricator keeps the cylinder seals working over long production runs.

science

Laboratory test-rig air supply

Conditions the supply to a bench-top test rig or pilot plant: the 40 um filter keeps particulate and water out of sensitive instruments, the low-pressure regulator trims the supply down for the rig, and the gauge gives a local psi readout.

Is the GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8 the Right Station?

Start with the port step: this unit is size 400 with NPT3/8 ports, one step up from 1/2 in alternatives in the range if your circuit needs more capacity - match the size to the air demand of the machine rather than the pipe alone. The filter carries the standard 40 um element; if the application needs finer filtration, the 5 um (W) grade is available in the same series. The differential-pressure drain bleeds the bowl automatically as pressure drops across the element, so no daily manual draining is needed. The low-pressure regulator suits circuits that run well below standard line pressure; its exact adjustment range is not published in the catalogue, so ask us to confirm it before ordering. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow for this series is published as curves, not a single rated figure, so send us your air demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8 FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Send us your air demand and line conditions and we will confirm the sizing against the datasheet on request before you order.

K means a reverse/check valve is fitted, so downstream pressure is held if the upstream supply is lost. The filter bowl uses a differential-pressure drain, which bleeds collected water automatically as the pressure drop across the element changes - no manual draining is required.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC40010LF2TK AirTAC F.R.L. Combination, NPT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40010LF2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.